Type designation
P30K
P37K
P45K
P55K
P75K
High/normal overload
1)
HO
NO
HO
NO
HO
NO
HO
NO
HO
NO
Typical shaft output at 550 V [kW/(hp)]
22
(30)
30
(40)
30
(40)
37
(50)
37
(50)
45
(60)
45
(60)
55
(75)
55
(75)
75
(100)
Typical shaft output at 690 V [kW/(hp)]
30
(40)
37
(50)
37
(50)
45
(60)
45
(60)
55
(75)
55
(75)
75
(100)
75
(100)
90
(125)
Enclosure protection rating IP20
B4
C3
C3
D3h
D3h
Enclosure protection rating IP21, IP55
C2
C2
C2
C2
C2
Output current
Continuous (525–550 V) [A]
36.0
43.0
43.0
54.0
54.0
65.0
65.0
87.0
87.0
105
Intermittent (60 s overload) (525–550 V)
[A]
54.0
47.3
64.5
59.4
81.0
71.5
97.5
95.7
130.5
115.5
Continuous (551–690 V) [A]
34.0
41.0
41.0
52.0
52.0
62.0
62.0
83.0
83.0
100
Intermittent (60 s overload) (551–690 V)
[A]
51.0
45.1
61.5
57.2
78.0
68.2
93.0
91.3
124.5
110
Continuous kVA (at 550 V) [kVA]
34.3
41.0
41.0
51.4
51.4
61.9
61.9
82.9
82.9
100
Continuous kVA (at 690 V) [kVA]
40.6
49.0
49.0
62.1
62.1
74.1
74.1
99.2
99.2
119.5
Maximum input current
Continuous (at 550 V) [A]
36.0
49.0
49.0
59.0
59.0
71.0
71.0
87.0
87.0
99.0
Intermittent (60 s overload) (at 550 V) [A]
54.0
53.9
72.0
64.9
87.0
78.1
105.0
95.7
129
108.9
Continuous (at 690 V) [A]
36.0
48.0
48.0
58.0
58.0
70.0
70.0
86.0
–
–
Intermittent (60 s overload) (at 690 V) [A]
54.0
52.8
72.0
63.8
87.0
77.0
105
94.6
–
–
Additional specifications
Maximum cable cross-section
5)
for mains
and motor [mm
2
] ([AWG])
150 (300 MCM)
Maximum cable cross-section
5)
for load
share and brake [mm
2
] ([AWG])
95 (3/0)
Maximum cable cross-section
2),5)
for mains
disconnect [mm
2
] ([AWG])
95, 70, 70
(3/0, 2/0, 2/0)
185, 150, 120
(350 MCM, 300
MCM, 4/0)
–
Estimated power loss
at rated maximum load [W]
3)
600
740
740
900
900
1100
1100
1500
1500
1800
Efficiency
4)
0.98
0.98
0.98
0.98
0.98
Table 8.12 B4, C2, C3 Enclosure, Mains Supply 525–690 V IP20/IP21/IP55 – Chassis/NEMA 1/NEMA 12 (FC 302 only), P30K–P75K
For fuse ratings, see chapter 8.7 Fuses and Circuit Breakers.
1) High overload=150% or 160% torque for a duration of 60 s. Normal overload=110% torque for a duration of 60 s.
2) The 3 values for the maximum cable cross-section are for single core, flexible wire, and flexible wire with sleeve, respectively.
3) Applies to dimensioning of frequency converter cooling. If the switching frequency is higher than the default setting, the power losses may
increase. LCP and typical control card power consumptions are included. For power loss data according to EN 50598-2, refer to
drives.danfoss.com/knowledge-center/energy-efficiency-directive/#/
4) Efficiency measured at nominal current. For energy efficiency class, see chapter 8.4 Ambient Conditions. For part load losses, see
drives.danfoss.com/knowledge-center/energy-efficiency-directive/#/.
5) Cable cross-section is regarded for copper cables.
Specifications
VLT
®
AutomationDrive FC 301/302
42
Danfoss A/S © 05/2018 All rights reserved.
MG33AT02
8
8