Type designation
P45K
P55K
P75K
P90K
Continuous at 575 V [A]
47
56
56
75
75
91
91
119
Intermittent at 575 V [A]
70
62
85
83
113
100
137
131
Maximum pre-fuses [A]
150
160
225
250
Additional specifications
Protection rating IP20 maximum cable cross-
section for mains and motor [mm
2
(AWG)]
50 (1)
150 (300 MCM)
Protection rating IP20 maximum cable cross-
section for brake and load sharing [mm
2
(AWG)]
50 (1)
95 (4/0)
Protection ratings IP21, IP55, IP66 maximum
cable cross-section for mains and motor
[mm
2
(AWG)]
50 (1)
150 (300 MCM)
Protection ratings IP21, IP55, IP66 maximum
cable cross-section for brake and load shar-
ing [mm
2
(AWG)]
50 (1)
95 (4/0)
Maximum cable cross-section
(2)
for mains dis-
connect [mm
2
(AWG)]
50, 35, 35 (1, 2, 2)
95, 70, 70 (3/0, 2/0, 2/0) 185, 150, 120 (350 MCM,
300 MCM, 4/0)
Estimated power loss
(3)
at rated maximum
load [W]
(4)
740
900
900
1100 1100
1500
1500
1800
Efficiency
(5)
0.98
1
High overload=150% or 160% torque for a duration of 60 s. Normal overload=110% torque for a duration of 60 s.
2
The 3 values for the maximum cable cross-section are for single core, flexible wire, and flexible wire with sleeve, respectively.
3
Applies for dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses may increase. LCP and
typical control card power consumptions are included. For more detailed efficiency values and part load losses according IEC/EN 61800-9-2 refer to
mydrive ecosmart on
. For efficiency class see
.
4
Efficiency measured at nominal current. For more detailed efficiency values and part load losses according IEC/EN 61800-9-2 refer to mydrive ecos-
mart on
. For efficiency class see
.
5
Measured using 5 m (16 ft) shielded motor cables at rated load and rated frequency. For more detailed efficiency values and part load losses ac-
cording IEC/EN 61800-9-2 refer to mydrive ecosmart on
. For efficiency class see
.
8.1.6 Mains Supply 3x525–690 V AC
Table 39: Enclosure, Mains Supply 3x525–690 V AC IP20/Protected Chassis, P1K1–P7K5
Type designation
P1K1
P1K5
P2K2
P3K0
P4K0
P5K5
P7K5
High/normal overload
(1)
HO NO HO NO HO NO HO NO HO NO HO
NO HO
NO
Typical shaft output [kW]
1.1
1.5
2.2
3.0
4.0
5.5
7.5
Typical shaft output [hp]
1.5
2.0
3.0
4.0
5.0
7.5
10
IP20/Chassis
A3
A3
A3
A3
A3
A3
A3
Output current
Continuous (3x525–550 V) [A]
2.1
2.7
3.9
4.9
6.1
9.0
11
Intermittent (3x525–550 V) [A]
3.2 2.3 4.1 3.0 5.9 4.3 7.4 5.4 9.2 6.7 13.5 9.9 16.5 12.1
Continuous (3x551–690 V) [A]
1.6
2.2
3.2
4.5
5.5
7.5
10
AJ300847815559en-000101 / 130R0337
86 | Danfoss A/S © 2020.09
Specifications
VLT® AQUA Drive FC 202
Design Guide