Power [kW
(hp)]
SIBA Type RK1 Littelfuse
Type RK1
Ferraz-
Shawmut
Type CC
Ferraz- Shaw-
mut Type RK1
Bussmann
Type JFHR2
Littel-
fuse
JFHR2
Ferraz-
Shawmut
JFHR2
(1)
Ferraz-
Shawmut
J
90 (125)
2028220-250
KLN-R-250
–
A6K-250-R
FWH-250
L50-
S-250
A50-P-250
HSJ-250
1
Ferraz-Shawmut A50QS fuses may substitute A50P fuses.
Table 80: Recommended Maximum Fuse, 525–600 V, Enclosure Sizes A, B, and C
Power [kW (hp)
Bussmann Type
RK1
Bussmann
Type J
Bussmann
Type T
Bussmann
Type CC
Bussmann
Type CC
Bussmann
Type CC
0.75–1.1 (1–1.5)
KTS-R-5
JKS-5
JJS-6
FNQ-R-5
KTK-R-5
LP-CC-5
1.5–2.2 (2.0– 3.0) KTS-R-10
JKS-10
JJS-10
FNQ-R-10
KTK-R-10
LP-CC-10
3.0 (4.0)
KTS-R15
JKS-15
JJS-15
FNQ-R-15
KTK-R-15
LP-CC-15
4.0 (5.0)
KTS-R20
JKS-20
JJS-20
FNQ-R-20
KTK-R-20
LP-CC-20
5.5 (7.5)
KTS-R-25
JKS-25
JJS-25
FNQ-R-25
KTK-R-25
LP-CC-25
7.5 (10.0)
KTS-R-30
JKS-30
JJS-30
FNQ-R-30
KTK-R-30
LP-CC-30
11–15 (15–20)
KTS-R-35
JKS-35
JJS-35
–
–
–
18 (24)
KTS-R-45
JKS-45
JJS-45
–
–
–
22 (30)
KTS-R-50
JKS-50
JJS-50
–
–
–
30 (40)
KTS-R-60
JKS-60
JJS-60
–
–
–
37 (50)
KTS-R-80
JKS-80
JJS-80
–
–
–
45 (60)
KTS-R-100
JKS-100
JJS-100
–
–
–
55 (75)
KTS-R-125
JKS-125
JJS-125
–
–
–
75 (100)
KTS-R-150
JKS-150
JJS-150
–
–
–
90 (125)
KTS-R-175
JKS-175
JJS-175
–
–
–
Table 81: Recommended Maximum Fuse, 525–600 V, Enclosure Sizes A, B, and C
Power [kW (hp)
SIBA Type RK1
Littelfuse Type RK1
Ferraz Shawmut Type RK1
Ferraz Shawmut J
0.75–1.1 (1–1.5)
5017906-005
KLS-R-005
A6K-5-R
HSJ-6
1.5–2.2 (2.0– 3.0)
5017906-010
KLS-R-010
A6K-10-R
HSJ-10
3.0 (4.0)
5017906-016
KLS-R-015
A6K-15-R
HSJ-15
4.0 (5.0)
5017906-020
KLS-R-020
A6K-20-R
HSJ-20
5.5 (7.5)
5017906-025
KLS-R-025
A6K-25-R
HSJ-25
7.5 (10.0)
5017906-030
KLS-R-030
A6K-30-R
HSJ-30
11–15 (15–20)
5014006-040
KLS-R-035
A6K-35-R
HSJ-35
18 (24)
5014006-050
KLS-R-045
A6K-45-R
HSJ-45
22 (30)
5014006-050
KLS-R-050
A6K-50-R
HSJ-50
AJ300847815559en-000101 / 130R0337 | 133
Danfoss A/S © 2020.09
Electrical Installation
Considerations
VLT® AQUA Drive FC 202
Design Guide