Option
Function
[195]
RS Flipflop 3
See
parameter group 13-1* Comparators
.
[196]
RS Flipflop 4
See
parameter group 13-1* Comparators
.
[197]
RS Flipflop 5
See
parameter group 13-1* Comparators
.
[198]
RS Flipflop 6
See
parameter group 13-1* Comparators
.
[199]
RS Flipflop 7
See
parameter group 13-1* Comparators
.
[221]
IGBT cooling
Use this option for handling the overcurrent trips. When the drive detects an overcurrent condition,
it shows
alarm 13, Overcurrent
and triggers a reset. If the overcurrent condition occurs for the 3
rd
time in a row, the drive shows
alarm 13, Overcurrent
and initiates a 3-minute delay before the next
reset.
[222]
Homing OK
NOTICE
This option is available only with software version 48.xx for VLT® AutomationDrive FC 302.
Homing is completed with the homing function selected in
parameter 17-80 Homing Function
.
[223]
On target
NOTICE
This option is available only with software version 48.xx for VLT® AutomationDrive FC 302.
Positioning is completed and the on-target signal is sent when the actual position is within
parame-
ter 3-05 On Reference Window
for the duration of
parameter 3-09 On Target Time
and the actual speed
does not exceed
parameter 3-05 On Reference Window
.
[224]
Position limit
NOTICE
This option is available only with software version 48.xx for VLT® AutomationDrive FC 302.
The position error exceeds the value in
parameter 4-71 Maximum Position Error
for the time set in
parameter 4-72 Position Error Timeout
.
[225]
Position error
NOTICE
This option is available only with software version 48.xx for VLT® AutomationDrive FC 302.
The position is outside the limits set in
parameter 3-06 Minimum Position
and
parameter 3-07 Maxi-
mum Position
.
[226]
Touch on target
NOTICE
This option is available only with software version 48.xx for VLT® AutomationDrive FC 302.
Touch probe positioning active. The drive monitors the touch probe sensor input.
[231]
In power lim. mot.
[232]
In power lim. gen.
[233]
In power limit
Parameter Setup
Operating Guide | VLT® Extended Relay Card MCB 113
AQ322553864968en-000101 / 130R0353| 37
Danfoss A/S © 2020.01
Summary of Contents for MCB 113
Page 2: ......