Option
Function
[95]
Evacuation
Evacuation Mode is a feature for lift application to enable drives to operate at reduced DC voltage for
evacuation of the people if there is power failure. When the feature is activated, undervoltage limits and
enable voltage limits is reduced so that the drive can be operated with 230 V single-phase UPS-supply.
[96]
Mains loss
Select to improve kinetic back-up. When the mains voltage goes back to a level that is close to (but still
lower than) the detection level, the output speed increases and kinetic back-up remains active. To avoid
this situation, send a status signal to the drive. When the signal on the digital input is low (0), the drive
forcibly turns off the kinetic back-up.
NOTICE
Only available for pulse inputs at terminals 32/33.
[97]
Mains loss in-
verse
When the signal on the digital input is high (1), the drive forcibly turns off the kinetic back-up. For more
details, see the description of
[96] Mains loss
.
NOTICE
Only available for pulse inputs at terminals 32/33.
[98]
Start edge trig-
gered
Edge-triggered start command. Keeps the start command alive. It can be used for a start push key.
[100]
Safe option re-
set
Resets the safety option. Available only when the safety option is mounted.
[106]
Set master
home
NOTICE
This option is available only with IMC software version 48.XX.
Sets actual master position to the value of
parameter 17-88 Master Home Position
.
[107]
Target Inverse
NOTICE
This option is available only with IMC software version 48.XX.
Changes the sign of the set target position. For example, if the set target is 1000, the activation of this
option changes the value to -1000.
[108]
Enable Master
Offset
NOTICE
This option is available only with IMC software version 48.XX.
Activates the master offset selected in
parameter 3-26 Master Offset
when
parameter 17-93 Master Offset
Selection
has a selection from
[1] Absolute
to
[5] Relative Touch Sensor
.
Parameter Setup
Operating Guide | VLT® Extended Relay Card MCB 113