Option
Function
[105]
Torque rel to rated
motor torque 0–
20 mA
The torque is related to the motor torque setting.
[106]
Power 0–20 mA
Taken from
parameter 1-20 Motor Power [kW]
.
[107]
Speed 0–20 mA
Taken from
parameter 3-03 Maximum Reference
. 20 mA = value in
parameter 3-03 Maximum Reference
.
[108]
Torque ref. 0–
20 mA
Torque reference related to 160% torque.
[109]
Max. out freq 0–
20 mA
In relation to
parameter 4-19 Max Output Frequency
.
[130]
Output freq. 4–
20 mA
0 Hz = 4 mA, 100 Hz = 20 mA.
[131]
Reference 4–
20 mA
Parameter 3-00 Reference Range [0] Min.–Max.
0% = 4 mA; 100% = 20 mA.
Parameter 3-00 Reference
Range [1] -Max.–+Max.
-100% = 4 mA; 0% = 12 mA; +100% = 20 mA.
[132]
Feedback 4–
20 mA
[133]
Motor cur. 4–
20 mA
The value is taken from
parameter 16-37 Inv. Max. Current
. The inverter maximum current (160% cur-
rent) is equal to 20 mA. Example: Inverter normal current (11 kW) = 24 A. 160% = 38.4 A. Motor nor-
mal current = 22 A, readout 11.46 mA.
16 mA � 22 �
38 . 4 �
= 9 . 17 mA
If the normal motor current is equal to 20 mA, the output setting of
parameter 6-52 Terminal 42 Output
Max Scale
is:
�
VLT, Max
× 100
�
Motor, Norm
= 38 . 4 × 100
22
= 175 %
[134]
Torque % lim. 4–
20 mA
The torque setting is related to the setting in
parameter 4-16 Torque Limit Motor Mode
.
[135]
Torque % nom 4–
20 mA
The torque setting is related to the motor torque setting.
[136]
Power 4–20 mA
Taken from
parameter 1-20 Motor Power [kW]
.
[137]
Speed 4–20 mA
Taken from
parameter 3-03 Maximum Reference
. 20 mA = value in
parameter 3-03 Maximum Reference
.
[138]
Torque 4–20 mA
Torque reference related to 160% torque.
[139]
Bus ctrl. 0–20 mA
An output value set from fieldbus process data. The output works independently of internal functions
in the drive.
[140]
Bus ctrl. 4–20 mA
An output value set from fieldbus process data. The output works independently of internal functions
in the drive.
[141]
Bus ctrl. 0–20 mA,
timeout
Parameter 4-54 Warning Reference Low
defines the behavior of the analog output if a fieldbus timeout
occurs.
[142]
Bus ctrl. 4–20 mA,
timeout
Parameter 4-54 Warning Reference Low
defined the behavior of the analog output if a fieldbus timeout
occurs.
[150]
Max. out freq 4–
20 mA
In relation to
parameter 4-19 Max Output Frequency
.
Parameter Setup
Operating Guide | VLT® Extended Relay Card MCB 113
AQ322553864968en-000101 / 130R0353
44 | Danfoss A/S © 2020.01