Option
Function
[115]
Home sensor
NOTICE
This option is available only with IMC software version 48.XX.
Normally-open contact for defining the home position. The function is defined in
parameter 17-80 Hom-
ing Function
.
[116]
Home sensor
inv.
NOTICE
This option is available only with IMC software version 48.XX.
Normally-closed contact for defining the home position. The function is defined in
parameter 17-80 Hom-
ing Function
.
[117]
Touch sensor
NOTICE
This option is available only with IMC software version 48.XX.
Normally-open contact. Serves as a reference for touch probe positioning.
[118]
Touch sensor
inv.
NOTICE
This option is available only with IMC software version 48.XX.
Normally-closed contact. Serves as a reference for touch probe positioning.
[119]
Speed mode
NOTICE
This option is available only with IMC software version 48.XX.
Select the speed mode when
[9] Positioning
or
[10] Synchronization
is selected in
parameter 1-00 Configu-
ration Mode
. Speed reference is set by reference resource 1 or fieldbus REF1 relative to
parameter 3-03
Maximum Reference
.
[122]
Position vir.
master
NOTICE
This option is available only with IMC software version 48.XX.
Activates position-controlled virtual master when
[10] Synchronization
is selected in
parameter 1-00 Con-
figuration Mode
. When the option is selected, the following occurs:
•
Target position is set by Fieldbus Pos Ref or preset target is as defined in
parameter 3-20 Preset Target
.
•
Speed is set relative to
parameter 3-27 Virtual Master Max Ref
by the source selected in
parameter 3-15
Reference Resource 1
or fieldbus REF1.
•
Acceleration and deceleration are set as defined in
parameter group 3-6* Ramp 3
.
Parameter Setup
Operating Guide | VLT® Extended Relay Card MCB 113