CAUTION
RISK OF FIRE OR EXPLOSION
l
Do not recharge, disassemble, or dispose of in fire.
1.
Locate the RTC battery holder on the control board of the control unit.
2.
Pull from the handle next to the text RTC BAT.
1
e3
0b
h4
67
.1
1
Figure 56: Location of the RTC Battery
1
The handle
Ü
The battery holder slides out.
3.
To remove the battery, push it on the tooth side and slide it out of the plastic holder.
1
e3
0b
h4
68
.1
1
Figure 57: Replacing the Battery
1
The tooth
4.
To put a new battery in place, start from the opposite side and slide it into the slot in the holder, the plus side towards the tooth.
The correct battery type is a coin type lithium battery BR1632.
5.
Push the holder back into the control board.
9.4
Removing the Fan Assembly
1.
Remove the 2 M5x10 screws (141L3849) and open the fan cover.
Use a TX25 bit to remove the screws.