[72]
Logic Rule 2
See par. group 13-4*. If Logic Rule 2 is
evaluated as TRUE, the output will go
high. Otherwise, it will be low.
[73]
Logic Rule 3
See par. group 13-4*. If Logic Rule 3 is
evaluated as TRUE, the output will go
high. Otherwise, it will be low.
[74]
Logic Rule 4
See par. group 13-4*. If Logic Rule 4 is
evaluated as TRUE, the output will go
high. Otherwise, it will be low.
[75]
Logic Rule 5
See par. group 13-4*. If Logic Rule 5 is
evaluated as TRUE, the output will go
high. Otherwise, it will be low.
[80]
SL Digital Output
A
See
. The output
will go high whenever the Smart Logic
Action [38]
Set dig. out. A
high is
executed. The output will go low
whenever the Smart Logic Action [32] Set
dig. out. A low is executed.
[81]
SL Digital Output
B
See
. The input
will go high whenever the Smart Logic
Action [39]
Set dig. out. A
high is
executed. The input will go low
whenever the Smart Logic Action [33]
Set
dig. out. A low
is executed.
[82]
SL Digital Output
C
See
. The input
will go high whenever the Smart Logic
Action [40]
Set dig. out. A
high is
executed. The input will go low
whenever the Smart Logic Action [34]
Set
dig. out. A low
is executed.
[83]
SL Digital Output
D
See
. The input
will go high whenever the Smart Logic
Action [41]
Set dig. out. A
high is
executed. The input will go low
whenever the Smart Logic Action [35]
Set
dig. out. A low
is executed.
[84]
SL Digital Output
E
See
. The input
will go high whenever the Smart Logic
Action [42]
Set dig. out. A
high is
executed. The input will go low
whenever the Smart Logic Action [36]
Set
dig. out. A low
is executed.
[85]
SL Digital Output
F
See
. The input
will go high whenever the Smart Logic
Action [43]
Set dig. out. A
high is
executed. The input will go low
whenever the Smart Logic Action [37]
Set
dig. out. A low
is executed.
[120] Local reference
active
Output is high when
=
[2] Local or when
= [0]
Linked to hand auto
at the same time as
the LCP is in hand on mode.
Reference site set
in
Local
referenc
e
active
[120]
Remote
reference
active
[121]
Reference site:
Local
[2]
1
0
Reference site:
Remote
[1]
0
1
Reference site:
Linked to Hand/
Auto
Hand
1
0
Hand -> off
1
0
Auto -> off
0
0
Auto
0
1
[121] Remote
reference active
Output is high when
=
Remote
[1] or
Linked to hand/auto
[0]
while the LCP is in [Auto on] mode. See
above.
[122] No alarm
Output is high when no alarm is present.
[123] Start command
active
Output is high when there is an active
start command (i.e., via digital input bus
connection or [Hand on] or [Auto on]),
and no stop or start command is active.
[124] Running reverse
Output is high when the adjustable
frequency drive is running counter
clockwise (the logical product of the
status bits ‘running’ AND ‘reverse’).
[125] Drive in hand
mode
Output is high when the adjustable
frequency drive is in hand on mode (as
indicated by the LED light above [Hand
on]).
[126] Drive in auto
mode
Output is high when the adjustable
frequency drive is in hand on mode (as
indicated by the LED light above [Auto
on]).
5-30 Terminal 27 Digital Output
Option:
Function:
[0]
*
No operation Functions are described under 5-3*
Digital
Outputs
5-31 Terminal 29 Digital Output
Option:
Function:
[0]
*
No operation Functions are described under 5-3*
Digital
Outputs
This parameter only applies to the FC 302
Parameter Descriptions
FC 300 Programming Guide
MG.33.MA.22 - VLT
®
is a registered Danfoss trademark
3-55
3
3