8.1.13 Wiring Configuration: Mechanical Brake Control
Table 94: Wiring Configuration for Mechanical Brake Control
Parameters
+24 V
+24 V
D IN
D IN
D IN
COM
D IN
D IN
D IN
D IN
+10 V
A IN
A IN
COM
A OUT
COM
R
1
R
2
e
3
0
b
u
0
9
3
.1
0
XD2.10
XD2.11
XD2.12
XD2.13
XD2.18
XD2.14
XD2.15
XD2.16
XD2.17
XD2.19
XD2.6
XD2.7
XD2.8
XD2.9
XD2.5
XD2.4
XD2.21
XD2.22
XD2.23
XD2.24
XD2.25
XD2.26
Function
Setting
Parameter 5-40 Function Relay
[32] Mech. brake ctrl.
Parameter 5-10 Terminal 18 Digital Input
[8] Start*
Parameter 5-11 Terminal 19 Digital Input
[11] Start reversing
Parameter 1-71 Start Delay
0.2
Parameter 1-72 Start Function
[5] VVC+/ FLUX Clockwise
Parameter 1-76 Start Current
I
m,n
Parameter 2-20 Release Brake Current
Application dependent
Parameter 2-21 Activate Brake Speed [RPM]
Half of nominal slip of the motor
* = Default value
Notes/comments:
Terminal 18 in the parameter title corresponds to terminal XD2.12 in the control compartment.
Terminal 19 in the parameter title corresponds to terminal XD2.13 in the control compartment.
e
3
0
b
b
8
4
2
.1
1
2-21
2-21
1-71
1-71
1-76
Start (18)
Start
reversing (19)
Relay output
Open
Closed
Time
Current
Speed
Illustration 70: Mechanical Brake Control
AQ262139143212en-000301 / 130R0879
134 | Danfoss A/S © 2021.10
Wiring Configuration Examples
VLT® AutomationDrive FC 302
Operating Guide