82
•
Z-Trak2 features reference
Z-Trak2 3D Profiler Sensors
Display Name
Feature & Values
Description
Device
Version
& View
Any Edge
AnyEdge
The trigger is considered valid for any transition
on the line source signal.
Level High
LevelHigh
The trigger is considered valid while the line
source signal is high.
Profile Trigger Maximum
Frequency
profileTriggerMaxFrequency
Maximum number of profile triggers accepted
per second at current exposure time.
1.00
DFNC
Guru
Profile Trigger Frequency
profileTriggerFrequency
Reads the number of profile triggers sent to
“TriggerSelector=Profile Trigger” per second.
1.00
DFNC
Guru
Scan Trigger Status
frameBurstState
Indicates the current status of Scan Trigger
signal
1.00
DFNC
Expert
Inactive
Inactive
The scan is waiting for a trigger or the grab to
start.
Active
Active
The scan is active and acquiring profiles.
Delay Active
DelayActive
The scan trigger has been activated and is
delayed by the number of profiles specified by
the Trigger Delay feature.