90
•
Z-Trak2 features reference
Z-Trak2 3D Profiler Sensors
Event features
Display Name
Feature & Values
Description
Device
Version
& View
Timestamp Latch Cmd
timestampControlLatch
Latch the current timestamp internal counter
value in the timestampValue feature.
1.00
Expert
DFNC
Timestamp Value
timestampValue
Returns the 64-bit value of the timestamp,
which is the internal Clock timer or the PTP clock
timer, depending on the Timestamp Source
selection.
1.00
Expert
DFNC
Timestamp Source
timestampSource
Specifies the source used as the incrementing
signal for the Timestamp register.
1.00
Expert
DFNC
Internal Clock
InternalClock The timestamp source is generated by the
device internal clock. Refer to the
timestampTickFrequency feature for the time
base.
IEEE1588
IEEE1588 The timestamp source is controlled by the
network IEEE1588 protocol. This source is
automatically selected when PTP mode is
enabled.
Timestamp Tick
Frequency
timestampTickFrequency
Indicates the number of timestamp ticks (or
increments) during 1 second (frequency in Hz).
This feature changes depending on the
TimeStamp Source.
1.00
Expert
DFNC
Timestamp Latch Source
timestampLatchSource
Specifies the internal event or signal that will
latch the timestamp counter into the timestamp
buffer.
1.00
Expert
DFNC
Line Start
LineStart The timestamp is latched on profile trigger.
Timestamp Reset Source
timestampResetSource
Specifies the internal signal or physical input line
to use as the timestamp reset source.
1.00
Expert
DFNC
None
None No timestamp reset source is specified. Note
that the Timestamp reset command can still
reset the counter.
Line 1
Line1 Use input line 1 as the timestamp reset source.
Line 2
Line2 Use input line 2 as the timestamp reset source.
Action 2
Action2 Select the GigEVision Action Command 2 as the
timestamp reset source. This is a broadcast
command that multiple devices can respond to
simultaneously.
Timestamp Reset Line
Activation
timestampResetLineActivation
Specifies the activation mode to reset the
timestamp counter on the selected line of the
TimestampResetSource feature.
1.00
Beginner
DFNC
Falling Edge
FallingEdge Reset the timestamp counter on the falling edge
of the source signal.
Rising Edge
RisingEdge Reset the timestamp counter on the rising edge
of the source signal.
Any Edge
AnyEdge Reset the timestamp counter on the falling or
rising edge of the source signal.
Timestamp Reset Cmd
timestampControlReset
Resets the timestamp counter to 0. This Feature
resets both the internal Clock timer and the PTP
clock timer. Note that the PTP Mode must be
disabled first to reset the PTP clock timer.
1.00
Expert
DFNC