72
•
Z-Trak2 features reference
Z-Trak2 3D Profiler Sensors
Display Name
Feature & Values
Description
Device
Version
& View
Measurement Units
Scan3dDistanceUnit
Sets the measurement units for the profile X and
Z data (default is Micrometer).
1.00
DFNC
Beginner
Micrometer
Micrometer All X and Z values are in micrometer units.
Millimeter
Millimeter All X and Z values are in millimeter units.
Inch/1000
Inch_1000 All X and Z values are in thousands of an inch
(mil).
Z Scaler
heightScaler
Scaling factor to convert Z values to the units
specified by Measurement Units.
1.00
DFNC
Guru
X Scaler
widthScaler
Scaling factor to convert X values to the units
specified by Measurement Units.
1.00
DFNC
Guru
Pixel Format
PixelFormat
Pixel formats as defined by the GeniCam
standard.
1.00
Guru
Monochrome 8-Bit
Mono8 Monochrome 8-Bit data format. Only available in
Areascan mode.
3D Coordinate Z (16-bit)
Coord3D_C16 3D Coordinate: Z position (16-Bit)
3D Coordinate XZ (32-bit)
Coord3D_AC16 3D Coordinate: X and Z positions stored
in a 32-Bit value.
3D Coordinate XZRW
(64-bit)
Coord3D_ACR016 3D Coordinate: X and Z positions, Reflectance
and peak Width stored in a 64-bit value.
Monochrome 16-Bit
Mono16 Mono16: Monochrome 16-Bit
Invalid Data Flag
Scan3dInvalidDataFlag
Enables/Disables the encoding of invalid values
in the profile data.
1.00
Guru
True
True Enables the flagging of the invalid values in the
profile data.
False
False Disables the flagging of the invalid values in the
profile data.
Invalid Data Code
Scan3dInvalidDataValue
Specifies a numerical code that indicates an
invalid value in the profile data.
1.00
Guru