56
•
Multi-sensor systems
Z-Trak2 3D Profiler Sensors
Multi-sensor synchronization can be done manually. However, Z-Expert provides a Synchronization
wizard to help with the settings. All values can then be saved in a camera configuration file.
The following timing diagrams depict how some of the Multi-Sensor Sync parameters are set. The
diagrams do not include details about other synchronization settings such as exposure time or
profile rate.
External/
Internal
Signal
Trigger Delay (master) = 0
Exposure
Master
Slave1
Slave2
Group Trigger Delay
Trigger Delay
(Slave1)
Exposure
Group Trigger Delay
Trigger Delay (Slave2)
Exposure
Sequential Acquisition
Group Trigger Delay
Group Trigger Delay Mode = Master and Slaves
Figure 21. The external/internal signal triggers the master sensor. The Group Trigger Delay value determines
the earliest time at which the sensors can start exposure. The Trigger Delay value of each sensor is different
in a sequential acquisition.
External/
Internal
Signal
Exposure
Master
Slave1
Slave2
Group Trigger Delay
Exposure
Group Trigger Delay
Exposure
Synchronized Acquisition
Group Trigger Delay
Group Trigger Delay Mode = Master and Slaves
Figure 22. The external/internal signal triggers the master sensor. The Group Trigger Delay value determines
the earliest time at which the sensors can start exposure. All sensors start exposure at the same time.