42
•
Introduction to Z-Expert
Z-Trak2 3D Profiler Sensors
In this scan profile, the
measurement AOI is depicted in
bright green, and corresponds here
to the measurement area, i.e. the
largest area where measurements
can take place. The dark green
trapeze indicates the sensor area
that is used. The object profile is in
blue.
The X-axis coordinates appear at the
bottom, and the Z-axis values on
the left. The auto-hide menu
provides various display settings,
such as adding distance cursors, or
changing the color of the profile or
measurement AOI.
Tips:
•
Put the pointer on the profile to
display the X and Z values.
•
Use the mouse wheel to zoom in
or zoom out the profile.
•
Drag the profile to change its
location in the window.
The measurement AOI from the
above capture was reduced. The
dotted area represents the
measurement area.
The measurement AOI can be
reduced in the Z-axis. Here, the
height of the AOI was reduced.
Another snap was done. Notice that
the portion of the profile below the
measurement AOI was not recorded
because it lies outside the AOI.
Tips:
•
Drag the handles of the
measurement AOI to change its
dimensions.
•
Drag the handles of the
measurement AOI beyond the
dotted lines to recover the entire
measurement area.