Z-Trak2 3D Profiler Sensors
Z-Trak2 features reference
•
75
X-Axis features
Display Name
Feature & Values
Description
Device
Version
& View
Uniform X Step Size
uniformXStepSize
Specifies the Interval between horizontal
samples. This value is used only when "3D Data
Type" is set to "UniformX Z".
1.00
DFNC
Beginner
Uniform X Offset
uniformXOffset
Horizontal offset where measurement data starts.
1.00
DFNC
Beginner
Uniform X Points Per
Profile Mode
uniformXPointsPerProfileMode
Selects how the "Points Per Profile" will be
determined. When set to "UseMeasurementAOI"
the "Points Per Profile" will be calculated based on
AOI settings. When set to "Manual" the user must
set the "Points Per Profile" value.
1.00
DFNC
Guru
Use Measurement AOI
UseMeasurementAOI Uses the width of the MeasurementAOI to
determine the number of points per profile.
Manual
Manual The number of Points per profile is set by the
user.
Uniform X Interpolation
Limit
uniformXMaxInterpolationLimit
Specifies the maximum interpolation zone along
the X-axis. Only Z-values inside of this zone are
used for interpolation when re-sampling for
uniform spacing.
1.00
DFNC
Guru