78
•
Z-Trak2 features reference
Z-Trak2 3D Profiler Sensors
Display Name
Feature & Values
Description
Device
Version
& View
Encoder Count Mode
encoderCountMode
Sets if the Encoder Value increments or decrements
for each encoder pulse. This feature is available when
Encoder B Input (Quadrature mode) is not being
used.
1.00
DFNC
Expert
Increment
Increment Encoder value increments for each encoder pulse.
Decrement
Decrement Encoder value decrements for each encoder pulse.
Encoder Direction
encoderDirection
When Encoder Source A and B are used, this feature
sets the direction which the encoder must be moving
for the profile triggers to be generated. This feature
is only available when both phases of the encoder are
used.
1.00
DFNC
Expert
Forward
Forward Profile triggers are generated when the encoder is
moving in the Forward direction. The forward
direction of the encoder is determined by the phase A
leading B.
Reverse
Reverse Profile triggers are generated when the encoder is
moving in the Reverse direction. The reverse
direction of the encoder is determined by the phase B
leading A.
Encoder Divider
EncoderDivider
Selects the number of input pulses to get before
generating "Profile Trigger".
1.00
Expert
Profile Rate (Hz)
profileRate
Specifies the profile rate of the sensor, in Hz.
1.00
DFNC
Beginner
Encoder Status
1
EncoderStatus
Indicates whether the encoder is moving forward,
reverse or idle. When encoder phase A and B are
used, the direction is determined automatically.
1.00
Expert
Encoder Forward
EncoderUp The encoder is moving in the forward direction.
Phase A leads Phase B.
Encoder Reverse
EncoderDown The encoder is moving in the reverse direction. Phase
B leads Phase A.
Encoder Idle
EncoderIdle The encoder is not moving.
Encoder Reset
EncoderReset
Resets the "Encoder Value" to 0.
1.00
Expert
Encoder Value
EncoderValue
Indicates the current encoder counter value. In
quadrature mode, the Encoder value automatically
increments in the forward direction (phase AB) and
decrements in the reverse direction (phase BA). In
single phase mode, the Encoder Count Mode feature
determines whether the Encoder Value will increment
or decrement.
1.00
Expert
Encoder Maximum
Value
encoderMaximumValue
Indicates the maximum value of the encoder counter.
When this value is reached, the counter wraps-
around to 0.
1.00
DFNC
Guru
Encoder Value At Scan
Start
encoderValueAtScanStart
Indicates the encoder counter value at the start of
every new scan.
1.00
DFNC
Expert
Encoder Value At Scan
Stop
encoderValueAtScanStop
Indicates the encoder counter value at the stop of
every scan.
1.00
DFNC
Expert
Displacement Between
Samples Y
displacementY
Displacement between samples Y (um, mil, mm).
1.00
DFNC
Expert
Encoder Profile Trigger
Mode
EncoderOutputMode
Selects how the direction and position of the Encoder
will generate profile triggers.
1.00
Expert
Position
Position When the encoder moves in the opposite direction as
defined by Encoder Direction, the current position is
recorded. No profile triggers are generated until that
position is passed again.
1
The Encoder Status feature is set to
Encoder Idle
if no motion signal is detected for 65 ms from the shaft encoder inputs;
it will change to either
Encoder Forward
(
EncoderUp
) or
Encoder Reverse
(
EncoderDown
) as soon as motion is detected.