background image

Add up total length of system

If necessary, join two strips together using a 

jump connector or a soldered wire connection. 

Follow steps 4b-6b for each end of the jump 

connection, or 4a-6a for each end of the 

soldered wire connection.

Remove tape backing and stick Tetra

®

 flexible 

tape in place. Ensure the tape is firmly attached. 
NOTE: Securing with electrical grade silicone is 

also acceptable. 
To avoid water ingress or shorting to the mating 

surface, all product should be inspected for 

breaks in the adhesive backing or silicone cover 

prior to installation and any damaged product 

should be not be installed.
Do not remove, reposition, or lift the tape once 

the adhesive backing has made contact with the 

mounting surface. 

Mounting surface

Jumper 

connector

Add up total footage of the system to 

determine the appropriate number of 12VDC 

Class 2 Tetra

®

 power supplies to use based on 

the Power Supply Loading chart on last page.

If installing multiple power supplies, keep them 

at least 2” (50.8mm) apart end to end and 4” 

(101.6mm) apart along the sides.

Electrical Connections

4”

2”

Power supply

Power supply

Power supply

Power supply

NOTE: Do not use connectors pre-filled with silicone 

grease/mineral base protective grease or use silicone 

grease to seal connections.

7

1

2

8

Wire AC line to power supplies in accordance with 

the applicable local, state, and country electrical 

codes. Connect black to black or brown, white to 

white or blue, and green to green using 18 AWG 

(0.82mm

2

) wire connectors. 

Connect the red wire (+) of the LED system to 

the red wire (+) of the power supply. Connect 

the black wire (-) of the LED system to the black 

or blue wire (-) of the power supply.

AC line

Black to black 

or brown (-)

Green to green

White to white 

or blue (+)

Power supply

To Flexible Tape 

or Lead Connector Wires

Red (+)

Red (+)

Black (-)

Black or blue (-) 

3

4

Tetra

®

 LED Tape Gen 2

Installation Guide

4

Summary of Contents for GE current Tetra GETP35-2

Page 1: ...ly in host signs that have been identified in the installation instructions and where the input rating of the retrofit kit does not exceed the input rating of the sign Installation of this LED retrofi...

Page 2: ...ited to use in dry and damp locations Water exclusion must be determined in the end product The grounding and bonding of the LED Driver shall be done in accordance with National Electric Code NEC Arti...

Page 3: ...ad and a black wire to the pad Heat shrink Silicone cover Red Black Seal the soldering points with electrical silicone Replace the silicone cover and secure it by shrinking a piece of heat shrink over...

Page 4: ...er of 12VDC Class 2 Tetra power supplies to use based on the Power Supply Loading chart on last page If installing multiple power supplies keep them at least 2 50 8mm apart end to end and 4 101 6mm ap...

Page 5: ...eater than 12 7 mm 1 2 in diameter require a metal patch secured by screws or rivets and caulked with non hardening caulk Smaller openings may be sealed with non hardening caulk 5 Existing Signs Only...

Page 6: ...re of the power supply Shadows Re route supply wire and secure to the back of the can with silicone Adjust wire connector orientation so that it does not cover any LEDs Adjust LED layout to ensure uni...

Page 7: ...indtr ngning eller kortslutning til den parringsoverflade skal alt produkt inspiceres for brud i kl bebekl dningen eller silikoneovertr kket inden installation og et beskadiget produkt b r ikke instal...

Page 8: ...anwendungen ist ebenfalls akzeptabel Um das Eindringen von Wasser oder Kurzschl sse auf der Anschlussoberfl che zu vermeiden sollte das gesamte Produkt vor der Installation auf Br che in der Klebeschi...

Page 9: ...ERKING Beveiligen met siliconen van elektrische kwaliteit is ook toegestaan Om contact met water en kortsluiting op de contactoppervlakte te voorkomen dienen alle producten voor installatie te worden...

Page 10: ...auf Br che in der Klebeschicht auf der R ckseite oder in der Silikonabdeckung berpr ft werden Besch digte Produkte d rfen nicht installiert werden Band nicht entfernen neu positionieren oder anheben...

Page 11: ...ts circuits la surface de contact tous les produits doivent tre inspect s avant l installation pour d tecter toute rupture du support adh sif ou de la bande protectrice en silicone Aucun produit endom...

Page 12: ...erisca saldamente NOTA consentito anche il fissaggio con silicone di grado elettrico Per evitare infiltrazioni d acqua o cortocircuiti in corrispondenza della superficie di accoppiamento prima dell in...

Page 13: ...unng at vann trenger inn eller tilkoblingsflaten kortsluttes anbefales det inspisere for brudd i det klebende underlaget eller silikondekselet over hele produktet f r installasjon Skadet produkt m ikk...

Page 14: ...d w ta my usuwamy pasek ochronny i przyklejamy ta m Tetra flexible w miejscu przeznaczenia Sprawdzamy czy ta ma mocno si trzyma UWAGA Dopuszcza si r wnie mocowanie silikonem do zastosowa elektrycznych...

Page 15: ...meza ATEN O A fixa o com silicone pr prio para material el trico tamb m aceit vel De forma a evitar o ingresso de gua ou curto circuitos com a superf cie de acoplamento todos os produtos devem ser ins...

Page 16: ...ra uso el ctrico Aseg rese de que no existen grietas en la parte adhesiva o en la cubierta de silicona antes de comenzar con la instalaci n para de esta forma evitar la penetraci n de agua o un cortoc...

Page 17: ...devre olu mas n nlemek i in t m r nlerin yap kan arkal klar ve silikon kapaklar montaj ncesinde kesintiler a kl klar i in incelenmeli hasarl r nler monte edilmemelidir Yap kan arkal k montaj y zeyiyl...

Page 18: ...s a szilikon bor t st s ha reped st vagy m s s r l st tal l rajtuk a term ket ne szerelje fel Ha a szalag ragaszt fel lete m r hozz rt a felsz nhez amelyen r gz teni k v nja azt ne t vol tsa el emelj...

Page 19: ...pavir iaus trumpo jungimo prie montuojant reik t patikrinti vis produkt ir sitikinti kad n ra lipnios galin s pus s arba silikonin s dangos l im ir pa eisto produkto nereik t montuoti Jei lipni pus j...

Page 20: ...aserat p laddningsdiagrammet f r str mf rs rjning p sista sidan 2 Om flera n taggregat installeras se till att avst ndet mellan dem r minst 50 8 mm nda mot nda och 101 6 mm i sidled 3 Anslut den r da...

Page 21: ...ns SIGN252 Rev 02 15 21 Enovia A 1012632 If you have any questions about these instructions or your specific application please contact support at tetra support gecurrent com For the latest install gu...

Reviews: