Troubleshooting

Symptom

Solution

All letters are OFF

•  Check AC input connection and/or check circuit breaker.

•  Check wire connection(s) at the Tetra

® 

LED System and power supply for improper termination(s) or short circuits.

•  Properly terminate or replace the wire connection(s).

•  Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the power supply and the white 

wire (-) of the LED strip to the black or blue wire (-) of the power supply.

Some LEDs appear 

dim OR not 

illuminated

•  Ensure the overall length of the Tetra

® 

LED System does not exceed the maximum load.

•  Ensure the length of supply wire is equal to or below the recommended remote mounting distance.

•  Verify that each connector between the affected LEDs and power supply is fully engaged by applying pressure on the cover 

verifying that the tabs have clicked into place and their is good electrical contact.

•  Check wire connection(s) at the Tetra

® 

LED System and power supply for improper termination(s) or short circuits. 

Properly terminate or replace the wire connection(s).

•  Check that connections are the red wire (+) of the LED strip to the red wire (+) of the power supply and the black wire 

(-) of the LED strip to the black or blue wire (-) of the power supply.

Shadows

•  Re-route supply wire and secure to the back of the can with silicone. Adjust wire connector orientation so that it does 

not cover any LEDs.

•  Adjust LED layout to ensure uniformity of illumination on the face of the letter.

18 AWG/0.82 mm

2

 

Supply Wire

16 AWG/1.31 mm

2

 

Supply Wire

14 AWG/2.08 mm

2

 

Supply Wire

12 AWG/3.31 mm

2

 

Supply Wire

25W Power Supply

120 ft./36.6 m

60W Power Supply

20 ft./6.1 m

30 ft./9.1 m

50 ft./15.2 m

86 ft./26.2 m

180W Power Supply

20 ft./6.1 m

30 ft./9.1 m

50 ft./15.2 m

86 ft./26.2 m

SKU

Rating

25W Power Supply

60W Power Supply

180W Power Supply

GETP35-2

GETP40-2

GETP50-2

GETP60-2

4.5W/m (1.37W/ ft.)

4m/13 ft.

10m/32 ft.

10m/32 ft. per output channel

30m/96 ft. per power supply

GETPH35-2

GETPH40-2

GETPH50-2

GETPH60-2

10.6W/m(3.22W/ ft.)

1.7m/5.6 ft.

4m/13 ft.

4m/13 ft. per output channel

12m/39 ft. per power supply

GETPRD-2

3.6W/m (1.08W/ ft.)

5m/16.4 ft.

12m/39 ft.

12m/39 ft. per output channel

36m/117 ft. per power supply

GETPGL-2

2.4W/m(0.75W/ ft.)

7m/23 ft.

15m/49 ft.

15m/49 ft. per output channel

45m/147 ft. per power supply

GETPBL-2

4.5W/m(1.37W/ ft.)

4m/13 ft.

10m/32 ft.

10m/32 ft. per output channel

30m/96 ft. per power supply

NOTE: For linear runs longer than 5m/16 ft. the center connection to the tape is recommended to minimize voltage drop.

Maximum Loading per Tetra 12 VDC Power Supply

Maximum Remote Mounting Distance

Tetra

®

 LED Tape Gen 2

Installation Guide

6

Summary of Contents for GE current Tetra GETP35-2

Page 1: ...ly in host signs that have been identified in the installation instructions and where the input rating of the retrofit kit does not exceed the input rating of the sign Installation of this LED retrofi...

Page 2: ...ited to use in dry and damp locations Water exclusion must be determined in the end product The grounding and bonding of the LED Driver shall be done in accordance with National Electric Code NEC Arti...

Page 3: ...ad and a black wire to the pad Heat shrink Silicone cover Red Black Seal the soldering points with electrical silicone Replace the silicone cover and secure it by shrinking a piece of heat shrink over...

Page 4: ...er of 12VDC Class 2 Tetra power supplies to use based on the Power Supply Loading chart on last page If installing multiple power supplies keep them at least 2 50 8mm apart end to end and 4 101 6mm ap...

Page 5: ...eater than 12 7 mm 1 2 in diameter require a metal patch secured by screws or rivets and caulked with non hardening caulk Smaller openings may be sealed with non hardening caulk 5 Existing Signs Only...

Page 6: ...re of the power supply Shadows Re route supply wire and secure to the back of the can with silicone Adjust wire connector orientation so that it does not cover any LEDs Adjust LED layout to ensure uni...

Page 7: ...indtr ngning eller kortslutning til den parringsoverflade skal alt produkt inspiceres for brud i kl bebekl dningen eller silikoneovertr kket inden installation og et beskadiget produkt b r ikke instal...

Page 8: ...anwendungen ist ebenfalls akzeptabel Um das Eindringen von Wasser oder Kurzschl sse auf der Anschlussoberfl che zu vermeiden sollte das gesamte Produkt vor der Installation auf Br che in der Klebeschi...

Page 9: ...ERKING Beveiligen met siliconen van elektrische kwaliteit is ook toegestaan Om contact met water en kortsluiting op de contactoppervlakte te voorkomen dienen alle producten voor installatie te worden...

Page 10: ...auf Br che in der Klebeschicht auf der R ckseite oder in der Silikonabdeckung berpr ft werden Besch digte Produkte d rfen nicht installiert werden Band nicht entfernen neu positionieren oder anheben...

Page 11: ...ts circuits la surface de contact tous les produits doivent tre inspect s avant l installation pour d tecter toute rupture du support adh sif ou de la bande protectrice en silicone Aucun produit endom...

Page 12: ...erisca saldamente NOTA consentito anche il fissaggio con silicone di grado elettrico Per evitare infiltrazioni d acqua o cortocircuiti in corrispondenza della superficie di accoppiamento prima dell in...

Page 13: ...unng at vann trenger inn eller tilkoblingsflaten kortsluttes anbefales det inspisere for brudd i det klebende underlaget eller silikondekselet over hele produktet f r installasjon Skadet produkt m ikk...

Page 14: ...d w ta my usuwamy pasek ochronny i przyklejamy ta m Tetra flexible w miejscu przeznaczenia Sprawdzamy czy ta ma mocno si trzyma UWAGA Dopuszcza si r wnie mocowanie silikonem do zastosowa elektrycznych...

Page 15: ...meza ATEN O A fixa o com silicone pr prio para material el trico tamb m aceit vel De forma a evitar o ingresso de gua ou curto circuitos com a superf cie de acoplamento todos os produtos devem ser ins...

Page 16: ...ra uso el ctrico Aseg rese de que no existen grietas en la parte adhesiva o en la cubierta de silicona antes de comenzar con la instalaci n para de esta forma evitar la penetraci n de agua o un cortoc...

Page 17: ...devre olu mas n nlemek i in t m r nlerin yap kan arkal klar ve silikon kapaklar montaj ncesinde kesintiler a kl klar i in incelenmeli hasarl r nler monte edilmemelidir Yap kan arkal k montaj y zeyiyl...

Page 18: ...s a szilikon bor t st s ha reped st vagy m s s r l st tal l rajtuk a term ket ne szerelje fel Ha a szalag ragaszt fel lete m r hozz rt a felsz nhez amelyen r gz teni k v nja azt ne t vol tsa el emelj...

Page 19: ...pavir iaus trumpo jungimo prie montuojant reik t patikrinti vis produkt ir sitikinti kad n ra lipnios galin s pus s arba silikonin s dangos l im ir pa eisto produkto nereik t montuoti Jei lipni pus j...

Page 20: ...aserat p laddningsdiagrammet f r str mf rs rjning p sista sidan 2 Om flera n taggregat installeras se till att avst ndet mellan dem r minst 50 8 mm nda mot nda och 101 6 mm i sidled 3 Anslut den r da...

Page 21: ...ns SIGN252 Rev 02 15 21 Enovia A 1012632 If you have any questions about these instructions or your specific application please contact support at tetra support gecurrent com For the latest install gu...

Reviews: