Multiple Bar Installation Details

Input voltage : 120VAC - 277VAC, 50/60Hz

Troubleshooting

Symptom

Solution

All LED fixtures 

are not 

illuminated

• Check leader cable connection and/or check circuit breaker.

• Check plug connectors on the LED fixtures for improper connections or short circuits.

• Ensure leader cable is securely connected to the female plug connector on the first LED luminaire.

Some LED 

fixtures are not 

illuminated

• Check plug connectors on the LED fixtures for improper connections or short circuits.

• Ensure any jumper cables are securely connected between the male/female plug connectors 

of the LED fixtures.

GEHLxxHyyz3
*Key for xx:  48=48 in., 96=96 in.

*Key for yy:  PP=Purple, PK=Pink, BR=Broad Spectrum

*Key for z:  Type "R", "B", "V", "I", "F"

Product Codes

Lamp 

Length

Product 

Code (SKU)

Description  

Code

Maximum Bars  

Per M25 14AWG Leader Cable

Maximum Bars 

Per Interconnected run or 

M19 18AWG Leader Cable

Qty of 

Mounting 

Clips

Electrical Loading Detail 

Typical Current (A)

For 

120VAC

For 

208VAC

For 

230VAC

For 

277VAC

For 

120VAC

For 

208VAC

For 

230VAC

For 

277VAC

Plastic 

Clips

Metal 

Clips

For 

120VAC

For 

208VAC

For 

230VAC

For 

277VAC

4 ft.

93137762

GEHL48HPPR3

38

65

72

83

14

20

26

26

2

2

0.30

0.17

0.16

0.14

93137763

GEHL48HPPF3

93137764

GEHL48HPPB3

93137765

GEHL48HPPV3

93137936

GEHL48HPKR3

93137937

GEHL48HPKF3

93137938

GEHL48HPKB3

93137939

GEHL48HBRI3

93137940

GEHL48HBRV3

8 ft.

93137941

GEHL96HPPR3

19

32

36

41

7

10

13

13

3

2

0.60

0.34

0.32

0.28

93137942

GEHL96HPPB3

93137943

GEHL96HPPV3

93137944

GEHL96HPKR3

93137945

GEHL96HPKB3

Summary of Contents for GE Current Arize Life2

Page 1: ...ential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense EN DA Den danske version af installationsvejledningen og sikk...

Page 2: ...s un environnement marin RISQUES D INCENDIE Respectez tous les codes locaux Visit LED com See table below for risk groups by model IEC 62471 UL Only IEC 62778 CE UKCA Only Part Number Risk Group Risk...

Page 3: ...ng flathead screws Approved 18 14 AWG 0 82 2 08 mm2 wire connectors in line splice connectors or alternative approved connectors End cap for connectors Optional Cable clamps Tools Required Components...

Page 4: ...tallation Alternately The required mounting clips may first be pressed onto the luminaire then the luminaire mounting clip assembly may be mounted on to the mounting surface using two 10 M5 self tappi...

Page 5: ...ng clip to a rigid flat mounting surface using two 10 M5 self tapping flathead screws along the intended run of luminaire To avoid stress and damage to luminaire the entire mounting surface should be...

Page 6: ...and twist the end cap clockwise to secure Remove end cap from the female connector Insert the male connector to the female connector Make sure the connector is fully engaged as indicted by hearing a...

Page 7: ...m Black or brown L White or blue N 0 10V Dimmer 120 277V AC Supply CLICK IMPORTANT GUIDELINES CONSEILS IMPORTANTS Cables shall not be concealed or extended through a wall floor ceiling or other parts...

Page 8: ...eader with dimming M19 Leader Cable EU UK 93142232 GECA30A18 BB06B 6ft 1 8m Leader 93142234 GECA30A18 BB10B 10ft 3 0m Leader 93142246 GECA30A18 BC06B 6ft 1 8m Leader with dimming 93142248 GECA30A18 BC...

Page 9: ...ing M25 Splitter NA EU UK 93142257 GECA30A14 CJ08B 8ft 2 4m Splitter with 1 M25 male to 5 M19 female connectors with dimming M25 Leader NA 93142253 GECA30A14 CG06B 6ft 1 8m Leader with dimming 15A NA...

Page 10: ...3 38 120V 65 208V 72 240V 83 277V GEHL96Hxxx3 19 120V 32 208V 36 240V 41 277V M19 18AWG Leader Cable GEHL48Hxxx3 max 14 120V 20 208V 26 240V 26 277V GEHL96Hxxx3 max 7 120V 10 208V 13 240V 13 277V M19...

Page 11: ...48 in 96 96 in Key for yy PP Purple PK Pink BR Broad Spectrum Key for z Type R B V I F Product Codes Lamp Length Product Code SKU Description Code Maximum Bars Per M25 14AWG Leader Cable Maximum Bars...

Page 12: ...t bend or otherwise exert excessive force on the connector during installation Using a screwdriver gently pry the luminaire out of the mounting clips Standard Clips Slim Clips METHOD 4 Replacement Ins...

Page 13: ...n maksimale l bel ngde pr lederkabel Armaturer m kun monteres ved hj lp af Current s standard eller slanke monteringsklemmer se Komponenter p kr vet p side 3 Line r layout OBS den anbefalede afstand m...

Page 14: ...imale Laufl nge pro F hrungskabel nicht berschreiten Leuchten d rfen nur mit den Standard oder d nnen Montageclips von Current montiert werden siehe Erforderliche Komponenten auf Seite 3 Lineares Layo...

Page 15: ...i n de barras m ltiples para asegurarse de que no excede la longitud m xima del cable principal Las luminarias deben montarse nicamente usando los clips de montaje est ndar o delgados de Current vea C...

Page 16: ...utta Valaisimet on asennettava k ytt en Currentin vakiomallisia tai taipuisia asennuskiinnikkeit katso sivun 3 kohtaa Tarvittavat osat Lineaarinen sijoittelu PHUOMAA Paremman optisen yhten isyyden vuo...

Page 17: ...maximale par c ble de raccordement Les luminaires doivent uniquement tre mont s l aide des clips de montage standard ou slim de Current voir Composants requis page 3 Disposition lin aire NOTE la dista...

Page 18: ...vagy v kony r gz t bilincseivel szerelhet k fel l sd A sz ks ges alkatr szek c r szt a 3 oldalon Line ris elrendez s MEGJEGYZ S a k t v g k z tti aj nlott t vols g nem lehet nagyobb mint 0 8 h velyk 2...

Page 19: ...are la lunghezza massima del tratto per un cavo principale Gli apparecchi devono essere montati utilizzando esclusivamente le clip di montaggio standard o sottili di Current vedere Componenti richiest...

Page 20: ...ysite did iausio nutiesimo ilgio numatyto pirminiam kabeliui viestuvai turi b ti montuojami tik naudojant iuolaikinius standartinius arba plonuosius tvirtinimo spaustukus i r kite 3 p Reikalingi kompo...

Page 21: ...leidkabel niet wordt overschreden Armaturen mogen alleen worden bevestigd met gebruikmaking van Current s standaard of slim montage clips zie Benodigde componenten op pagina 3 Lineaire layout OPMERKI...

Page 22: ...Armaturer m bare monteres ved hjelp av Currents standard eller smale festeklemmer se N dvendige komponenter p side 3 Linear oppsett MERK Den anbefalte avstanden mellom to ender b r ikke v re mer enn...

Page 23: ...wy o wietleniowe po czone bezpo rednio ze sob Przed rozpocz ciem monta u Zobacz Szczeg y instalacji wielu modu w lamp aby upewni si e nie przekroczysz maksymalnej d ugo ci ci gu na jednej ga zi kabla...

Page 24: ...Barras para garantir que n o excede o comprimento m ximo para cada cabo condutor As lumin rias apenas devem ser montadas seguindo o padr o da Current ou usando clipes de montagem estreitos ver Compon...

Page 25: ...onkontakten och vrid ndlocket medurs f r att f sta det G till METOD 3 p sidan 7 METOD 2 Direkt sammankopplade armaturer Innan installation p b rjas H nvisning till installationsuppgifterna f r flerblo...

Reviews: