Troubleshooting by Indication on the Remote Controller
277
Remote Controller Display
U2
Applicable Models
VRVII and -WII Series
Method of Error Detection
Detection of voltage of main circuit capacitor built in the
inverter and power supply voltage.
Error Decision Conditions
When the capacitor above only has a voltage of 360 V or
less (YL) and 210V or less (TL).
Supposed Causes
Power supply insufficient
Instantaneous failure
Open phase
Defective inverter PCB
Defective outdoor (outside) control PCB
Defective magnetic contact switch.