Si39-406
Safety Considerations
Installation Manual BS Unit
173
When wiring the power supply and connecting the remote controller wiring and
transmission wiring, position the wires so that the electric parts box lid can be securely
fastened.
Improper positioning of the electric parts box lid may result in electric shocks, fire or the
terminals overheating.
If the refrigerant gas leaks during installation, ventilate the area immediately.
Toxic gas may be produced if the refrigerant gas comes into contact with fire.
After completing the installation work, check that the refrigerant gas does not leak.
Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact
with a source of fire, such as a fan heater, stove or cooker.
Before touching electrical parts, turn off the unit.
Ground the air conditioner. Do not connect the ground wire to gas or water pipes,
lightning rod or a telephone ground wire.
Incomplete grounding may result in electric shocks.
Do not touch the switch with wet fingers.
Touching a switch with wet fingers can cause electric shock.
Install an leak circuit breaker, as required.
If an leak circuit breaker is not installed, electric shock may result.
Do not install the air conditioner in the following locations:
(a) where a mineral oil mist or an oil spray or vapor is produced, for example in a kitchen Plastic
parts may deteriorate and fall off or result in water leakage.
(b) where corrosive gas, such as sulfurous acid gas, is produced Corroding copper pipes or
soldered parts may result in refrigerant leakage.
(c) near machinery emitting electromagnetic waves Electromagnetic waves may disturb the
operation of the control system and result in a malfunction of the equipment.
(d) where flammable gases may leak, where there are carbon fiber or ignitable dust suspensions in
the air, or where volatile flammables such as thinner or gasoline are handled.
Operating the unit in such conditions may result in fire.
CAUTION
While following the instructions in this installation manual, insulate piping in order to
prevent condensation.
Improper piping insulation may result in water leakage and property damage.
Be very careful about product transportation.
Some products use PP bands for packaging. Do not use any PP bands for a means of
transportation. It is dangerous.
Safely dispose of the packing materials.
Packing materials, such as nails and other metal or wooden parts, may cause stabs or other
injuries. Tear apart and throw away plastic packaging bags so that children will not play with
them. If children play with a plastic bag which was not torn apart, they face the risk of
suffocation.
Summary of Contents for REYQ96MTJU
Page 1: ...Design Installation Testing Instruction R410A Heat Recovery 60Hz REYQ96MTJU Si39 406...
Page 6: ...Si39 406 iv Table of Contents...
Page 34: ...Installation Si39 406 28 General Information Flaring Procedure...
Page 68: ...Installation Si39 406 62 General Information Caution Caution label 3P124617 4P124614...
Page 114: ...Appendix Si39 406 108 General Information 3P135887 1...
Page 126: ...Appendix Si39 406 120 General Information 7 8 3 BS Unit BSVQ36MVJ BSVQ60MVJ 4D045338...
Page 128: ...Appendix Si39 406 122 General Information 7 9 2 Field Wiring REYQ96MTJU 3D042647A...
Page 156: ...Refrigerant Piping Si39 406 150 Installation Manual REYQ96MTJU...
Page 158: ...Refrigerant Piping Si39 406 152 Installation Manual REYQ96MTJU...
Page 230: ...Precautions for New Refrigerant R410A Si39 406 224 Precautions for New Refrigerant R410...
Page 236: ...375 Park Avenue Suite 3308 New York N Y 10152 info daikinac com www daikinac com...