Si33-105
Specifications
Specifications R407C PLUS Series Heat Recovery System
25
Wall Mounted Type
Notes:
"
1 Nominal cooling capacities are based on the following conditions:
Return air temperature : 27°C DB, 19°C WB, Outdoor temperature : 35°C DB
Equivalent ref. piping : 5m (Horizontal)
"
2 Nominal heating capacities are based on the following conditions:
Return air temperature : 20°C DB, Outdoor temperature : 7°C DB, 6°C WB
Equivalent ref. piping : 5m (Horizontal)
"
3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
Model
FXYAP40KV1
FXYAP50KV1
FXYAP63KV1
Power Supply
1 phase 50Hz
220-240V
1 phase 50Hz
220-240V
1 phase 50Hz
220-240V
"
"
"
"
1 Cooling Capacity
kW
4.5
5.6
7.1
"
"
"
"
2 Heating Capacity
kW
5.0
6.3
8.0
Casing Color
White (10Y9/0.5)
White (10Y9/0.5)
White (10Y9/0.5)
Dimensions: (H×W×D)
mm
360×1,050×200
360×1,250×200
360×1,250×200
Coil (Cross
Fin Coil)
Rows×Stages×Fin Pitch
mm
2×12×1.4
2×12×1.4
2×12×1.4
Face Area
m²
0.169
0.219
0.219
Fan
M
odel
QCL1165MQCL1185MQCL1185M
Type
Cross Flow Fan
Cross Flow Fan
Cross Flow Fan
Motor Output × Number
of Units
W
23
37
37
Air Flow Rate (H/L)
m³/min
11/9
13/11
15/12
Drive
Direct Drive
Direct Drive
Direct Drive
Temperature Control
Microprocessor Thermostat for
Cooling and Heating
Microprocessor Thermostat for
Cooling and Heating
Microprocessor Thermostat for
Cooling and Heating
Sound Absorbing Thermal Insulation Material
Foamed Polystyrene/ Foamed
Polyethylene
Foamed Polystyrene/ Foamed
Polyethylene
Foamed Polystyrene/ Foamed
Polyethylene
Air Filter
Resin Net (Washable)
Resin Net (Washable)
Resin Net (Washable)
Piping
Connections
Liquid Pipes
6.4mm (Flare Connection)
9.5mm (Flare Connection)
9.5mm (Flare Connection)
Gas Pipes
12.7mm (Flare Connection)
15.9mm (Flare Connection)
15.9mm (Flare Connection)
Drain Pipe
(mm)
VP20
(External Dia. 26 Internal Dia. 20)
VP20
(External Dia. 26 Internal Dia. 20)
VP20
(External Dia. 26 Internal Dia. 20)
Weight
kg
21
24
24
Safety Devices
Fuse
Thermal Protector for Fan Motor
Fuse
Thermal Protector for Fan Motor
Fuse
Thermal Protector for Fan Motor
Refrigerant Control
Electronic Expansion Valve
Electronic Expansion Valve
Electronic Expansion Valve
Standard Accessories
Operation Manual, Installation
Manual, Paper Pattern for Installation,
Insulation for Fitting, Screws, Clamps,
Insulation Tape, Installation Panel
Fixed Parts.
Operation Manual, Installation
Manual, Paper Pattern for Installation,
Insulation for Fitting, Screws,
Washers, Insulation Tape, Installation
Panel Fixed Parts.
Operation Manual, Installation
Manual, Paper Pattern for Installation,
Insulation for Fitting, Screws,
Washers, Insulation Tape, Installation
Panel Fixed Parts.
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Summary of Contents for R407C PLUS
Page 1: ...System R407C PLUS Series Heat Recovery System Si33 105 Service Manual ...
Page 11: ...Introduction Si33 105 x ...
Page 41: ...Specifications Si33 105 30 Specifications R407C PLUS Series Heat Recovery System ...
Page 147: ...Test Operation Si33 105 136 Test Operation R407C PLUS Series Heat Recovery System ...
Page 263: ...Si33 105 iv Index ...