SiBE04-808_B
Control Specification
Function and Control
52
RK(X)S20-35G2V1B9, ARXS20-35G3V1B
Limitation of current drooping and stop value according to the outdoor temperature
The current droops when outdoor temperature becomes higher than a certain level
(depending on the model).
20 class
25 class
35 class
Cooling
Heating
Cooling
Heating
Cooling
Heating
A
(A)
9.25
9.25
9.25
B
(A)
Normal mode
6.0
7.5
6.25
7.5
8.25
ECONO mode
3.25
3.25
3.25
C
(A)
Normal mode
5.25
6.75
5.5
6.75
7.5
ECONO mode
2.5
2.5
2.5