
SiBE04-808_B
Outdoor Unit - RK(X)S42G2V1B, ARXS42G2V1B
Removal Procedure
256
5
Turn the fan motor
fixing frame backward
and open the 2 hooks of
the fan motor lead wire.
6
Release the fan motor
lead wire.
When reassembling, put the
fan motor lead wire through
the back of the fan motor (so
as not to be entangled with
the outdoor fan).
7
Remove the 4 screws
and 4 rubber vibration
isolators to remove the
fan motor.
Step
Procedure
Points
(R8189)
(R7627)
Lead wire
Outdoor fan
(R12215)
(R8190)
(R8191)