Printed Circuit Board Connector Wiring Diagram
SiBE04-808_B
25
Printed Circuit Board Connector Wiring Diagram
1.2.3 RK(X)S42G2V1B, ARXS42G2V1B
Connectors and
Other Parts
PCB (1): Control PCB
1) S20
Connector for electronic expansion valve coil
2) S40
Connector for overload protector
3) S70
Connector for fan motor
4) S80
Connector for four way valve coil
5) S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
6) U, V, W
Connector for compressor
7) HL1, HN1, S
Connector for terminal board
8) E (E2)
Connector for earth
9) HR1, HR2
Connector for reactor
10) LED A
LED for service monitor (green)
11) FU1, FU2
Fuse (3.15 A, 250 V)
12) FU3
Fuse (30 A, 250 V)
13) J4
Jumper for facility setting
∗
Refer to page 295 for detail.
14) J5
Jumper for improvement of defrost performance
∗
Refer to page 296 for detail.
15) V1, V3, V4
Varistor