SiBE04-808_B
Service Diagnosis
94
Part 6
Service Diagnosis
Troubleshooting with LED ......................................................................95
2. Problem Symptoms and Measures .......................................................96
3. Service Check Function ........................................................................97
Error Codes and Description ................................................................103
Indoor Unit PCB Abnormality ...............................................................104
Freeze-up Protection Control or Heating Peak-cut Control..................105
Fan Motor (DC Motor) or Related Abnormality.....................................107
Thermistor or Related Abnormality (Indoor Unit)..................................109
Signal Transmission Error (between Indoor Unit and Outdoor Unit) ....110
Unspecified Voltage (between Indoor Unit and Outdoor Unit) .............111
Outdoor Unit PCB Abnormality.............................................................112
OL Activation (Compressor Overload) .................................................114
4.10 Compressor Lock .................................................................................115
4.11 DC Fan Lock ........................................................................................116
4.12 Input Overcurrent Detection .................................................................117
4.13 Four Way Valve Abnormality................................................................118
4.14 Discharge Pipe Temperature Control...................................................120
4.15 High Pressure Control in Cooling .........................................................122
4.16 Compressor System Sensor Abnormality ............................................124
4.17 Position Sensor Abnormality ................................................................126
4.18 DC Voltage / Current Sensor Abnormality (20/25/35/42 Class) ...........129
4.19 CT or Related Abnormality (50 Class)..................................................130
4.20 Thermistor or Related Abnormality (Outdoor Unit) ...............................132
4.21 Electrical Box Temperature Rise..........................................................134
4.22 Radiation Fin Temperature Rise ..........................................................136
4.23 Output Overcurrent Detection ..............................................................138
4.24 Refrigerant Shortage ............................................................................140
4.25 Low-voltage Detection or Over-voltage Detection................................143
4.26 Signal Transmission Error on Outdoor Unit PCB (50 Class Only) .......145