Piping Diagrams
SiBE04-808_B
301
Appendix
RKS42G2V1B
RKS50G2V1B
REFRIGERANT FLOW
6.4CuT
COMPRESSOR
9.5CuT
7.9CuT
9.5CuT
9.5CuT
PROPELLER FAN
OUTDOOR UNIT
M
MUFFLER
(9.5CuT)
ACCUMULATOR
(6.4CuT)
4.8CuT
9.5CuT
9.5CuT
FIELD PIPING
HEAT EXCHANGER
7.9CuT
4.8CuT
MUFFLER
12.7CuT
7.9CuT
FIELD PIPING
6.4CuT
7.9CuT
COOLING
6.4CuT
φ
.4.0
×
ID
. 2.0CuT
OUTDOOR TEMPERATURE
THERMISTOR
HEAT EXCHANGER
THERMISTOR
MOTOR OPERATED
VALVE
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
LIQUID STOP
VALVE
GAS STOP
VALVE
FOUR WAY
VALVE
NORMALLY:OFF
DISCHARGE PIPE
THERMISTOR
3D059591
OUTDOOR UNIT
12.7CuT
12.7CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
PROPELLER FAN
MUFFLER
HEAT EXCHANGER
7.9CuT
7.9CuT
M
COMPRESSOR
12.7CuT
12.7CuT
7.9CuT
7.9CuT
4.0CuT
4.0CuT
CAPILLARY TUBE 4
CAPILLARY TUBE 2
CAPILLARY TUBE 3
CAPILLARY TUBE 1
12.7CuT
MUFFLER
12.7CuT
6.4CuT
12.7CuT
6.4CuT
6.4CuT
6.4CuT
FIELD PIPING
REFRIGERANT FLOW
FIELD PIPING
(12.7 CuT)
(6.4 CuT)
COOLING
4.0CuT
4.0CuT
OUTDOOR AIR TEMPERATURE
THERMISTOR
MUFFLER
WITH
FILTER
MOTOR OPERATED
VALVE
MUFFLER
WITH FILTER
LIQUID
STOP VALVE
GAS STOP VALVE
WITH SERVICE PORT
FOUR WAY
VALVE
NORMALLY:OFF
DISCHARGE PIPE
THERMISTOR
HEAT
EXCHANGER
THERMISTOR
3D051636N