Removal Procedure
10
Release the clamp of
the compressor relay
harness with pliers.
11
Detach the clamp and
release the thermistor
lead wires from the
hook.
12
Remove the screw.
Step
Procedure
Points
(R5277)
Compressor relay harness
(R5278)
Thermistor lead wire
Hook
Clamp
(R12316)