179
Removal Procedure
4
Detach the pivot from
the interlock shaft for
vertical blades with a
flat screwdriver.
5
Remove the swing
motor unit.
6
Detach the interlock
shaft from the swing
motor with a flat
screwdriver.
7
Remove the vertical
blade interlock with a
flat screwdriver.
Step
Procedure
Points
(R12270)
Vertical blade ASSY
Pivot
Interlock
shaft
(R8126)
Swing motor unit
(R8127)
Interlock shaft
(R10331)
Vertical blade interlock