Indoor Unit
SiBE04-808_B
173
Removal Procedure
6. Remove the display PCB.
The display PCB is
positioned on the rear side
of the signal receiver unit.
1
The figure shows the
connection of wire
harness for the display
PCB.
2
Unfasten the 4 hooks
and remove the display
PCB.
3
Disconnect the
connector [S49] from
the display PCB.
7. Remove the control PCB.
1
Unfasten the lower 2
hooks of the control
PCB.
Step
Procedure
Points
(R8094)
Display PCB
(R10318)
Hook
(R8096)
LED 3 (Green)
LED 1 (Green)
[S49]
LED 2 (Yellow)
(R8097)
Hook