Functions for FTX, FVXS Series
SiUS091601EA
47
Part 4 Functions and Control
Caution
FVXS series
3-D Airflow
FTX18/24UVJU only
Alternative repetition of vertical and horizontal swing motions enables uniform air-conditioning of
the entire room.
When the horizontal swing and vertical swing are both set to automatic operation, the airflow
becomes 3-D airflow. The horizontal and vertical swing motions are alternated and the airflow
direction changes in the order shown in the following diagram.
(1) The vertical blades (louvers) move from the right to the left.
(2) The horizontal blades (flaps) move downward.
(3) The vertical blades (louvers) move from the left to the right.
(4) The horizontal blades (flaps) move upward.
Airflow Selection
Setting
FVXS Series
Airflow direction can be set with the airflow selection switch.
Open the front panel.
Before opening the front panel, be sure to stop the operation and turn the breaker off.
Do not touch the aluminum fins (indoor heat exchanger) inside the indoor unit, as it may result in
injury.
Flap (up and down)
Cooling/Dry
Heating
Upward airflow
limit OFF
R4003397
R4003396
Upward airflow
limit ON
R4003394
R4003394
25°
90°
40°
90°
90°
20°
90°
20°
(R19554)
(2)
(4)
(3)
(1)
Air is blown from the upper outlet only.
Front panel
The blow pattern is automatically decided
depending on mode and conditions.
(Recommended and factory set.)
(R17866)
Summary of Contents for FTX-N Series
Page 18: ...SiUS091601EA 13 Part 2 Specifications 1 Specifications 14 Part 2 Specifications...
Page 198: ...Check SiUS091601EA 193 Part 6 Service Diagnosis 18 24 class R24538 1 2 3 4 Multimeter...
Page 201: ...SiUS091601EA Check Part 6 Service Diagnosis 196 18 24 class R24539 DC DC W V U...
Page 229: ...SiUS091601EA Piping Diagrams Part 8 Appendix 224 RXL15QMVJU RXL18UMVJU 3D100007 3D123368...
Page 230: ...Piping Diagrams SiUS091601EA 225 Part 8 Appendix RXL24UMVJU 3D107985A...