![background image](http://html1.mh-extra.com/html/daikin/ftx-n-series/ftx-n-series_service-manual_3332842192.webp)
Check
SiUS091601EA
187
Part 6 Service Diagnosis
FTX09/12/15NMVJU
1. Turn the power on.
2. Press the center of
TEMP
button and
OFF
button on the remote controller at the same time.
3. Select
T
with
TEMP
or
TEMP
button.
4. Press
FAN
button.
5. Press
FAN ONLY
button to start the power transistor test operation.
FTX18/24UVJU, FVXS series
1. Turn the power on.
2. Select FAN operation with the
Mode
button on the remote controller.
3. Press the center of the
Temp
button and the
Mode
button at the same time.
4. Select
T
with the
Temp
or
Temp
button.
5. Press the
Mode
button to start the power transistor test operation.
OFF
button
(R23157)
(R24537)
3, 4
2, 3, 5