Outdoor Unit
SiUS091601EA
39
Part 3 Printed Circuit Board Connector Wiring Diagram
4.4 RXL18/24UMVJU
Main PCB (PCB1)
1)
S
Connector for terminal block (indoor - outdoor transmission)
2)
S20
Connector for electronic expansion valve coil (White)
3)
S40
Connector for overload protector
4)
S70
Connector for DC fan motor
5)
S80
Connector for four way valve coil
6)
S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
7)
S201, 202
Connector for service monitor PCB (PCB2)
8)
CK1
Connector for voltage endurance test
9)
HL1, HN1
Connector for terminal block (power supply)
10)
E1, E2
Terminals for ground wire
11)
U, V, W
Connector for compressor
12)
FU1, FU2
Fuse (3.15 A, 250 V)
13)
FU3
Fuse (30 A, 250 V)
14)
V2, V3, V401
Varistor