Part 4 Functions and Control
48
When setting the airflow selection switch to
.
The air conditioner automatically decides the appropriate blowing pattern depending on the
operating mode/situation.
During dry operation, air is blown from upper air outlet, so that cold air does not come into direct
contact with people.
When setting the airflow selection switch to
.
Regardless of the operating mode or situation, air is blown from the upper air outlet.
Use this switch when you do not want air coming out of the lower air outlet (e.g., while sleeping).
Operating mode
Situation
Blowing pattern
Cooling
When the operation is
activated or when the room is
not fully cooled.
Air is blown from the upper
and lower air outlets in order
to reach the set temperature
quickly.
When the room has become
fully cool, or when 1 hour has
passed since turning on the air
conditioner.
Air is blown only from the
upper air outlet so that air
does not come into direct
contact with people and
indoor temperature is
equalized.
Heating
When the operation is
activated or when air emitted
is of low temperature.
Air is blown only from the
upper air outlet so that air
does not come into direct
contact with people.
At times other than the above
situations.
Air is blown from the upper
and lower air outlets so that
warm air is spread
throughout the whole room.
Dry
Whenever in DRY mode.
Air is blown only from the
upper air outlet so that air
does not come into direct
contact with people.
Fan
Whenever in FAN mode.
—
Automatic
Operates in the actual operation mode of the air conditioner according to
the descriptions in this table. (COOL or HEAT)
Summary of Contents for FTX-N Series
Page 18: ...SiUS091601EA 13 Part 2 Specifications 1 Specifications 14 Part 2 Specifications...
Page 198: ...Check SiUS091601EA 193 Part 6 Service Diagnosis 18 24 class R24538 1 2 3 4 Multimeter...
Page 201: ...SiUS091601EA Check Part 6 Service Diagnosis 196 18 24 class R24539 DC DC W V U...
Page 229: ...SiUS091601EA Piping Diagrams Part 8 Appendix 224 RXL15QMVJU RXL18UMVJU 3D100007 3D123368...
Page 230: ...Piping Diagrams SiUS091601EA 225 Part 8 Appendix RXL24UMVJU 3D107985A...