SiUS091601EA
Outdoor Unit
Part 3 Printed Circuit Board Connector Wiring Diagram
34
4. Outdoor Unit
4.1 RXL09QMVJU
Main PCB (PCB1)
1)
S20
Connector for electronic expansion valve coil
2)
S30
Connector for compressor
3)
S40
Connector for overload protector
4)
S71
Connector for DC fan motor
5)
S80
Connector for four way valve coil
6)
S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
7)
HL1, HN1, S
Connector for terminal block
8)
E1, E2
Terminal for ground wire
9)
HR1, HR2
Connector for reactor
10)
FU1, FU2
Fuse (3.15 A, 250 V)
11)
FU3
Fuse (20 A, 250 V)
12)
J6
Jumper for facility setting
Refer to page 217 for details.
13)
LED A
LED for service monitor (green)
14)
V2, V3, V150
Varistor