Functions for FTX, FVXS Series
SiUS091601EA
57
Part 4 Functions and Control
Note(s)
Note(s)
For dry operation, the temperature cannot be set with a remote controller, but the target
temperature is shifted internally.
2.10 POWERFUL Operation
Outline
In order to exploit the cooling and heating capacity to full extent, the air conditioner can be operated
by increasing the indoor fan rotating speed and the compressor frequency.
Details
When
POWERFUL
button is pressed, the fan speed and target temperature are converted to the
following states for 20 minutes.
Ex: POWERFUL operation in cooling
POWERFUL operation cannot be used together with ECONO, COMFORT AIRFLOW, or
OUTDOOR UNIT QUIET operation.
Operation mode
Fan speed
Target temperature
COOL
H tap +
A
rpm
18°C (64.4°F)
DRY
Dry rotating speed +
A
rpm
Lowered by 2.5°C (4.5°F)
HEAT
H tap +
A
rpm
B
FAN
H tap +
A
rpm
—
AUTO
Same as cooling/heating in
POWERFUL operation
The target temperature is kept
unchanged.
A
= FTX09/12/15NMVJU: 80 (rpm)
FTX18/24UVJU: 50 (rpm)
FVXS series: 30 ~ 40 (rpm)
B
= FTX09/12/15NMVJU: 31°C (87.8°F)
FTX18/24UVJU: 31.5°C (88.7°F)
FVXS series: 32°C (89.6°F)
(R24589)
Target temp.
Fan
A
rpm
H tap
Set tap
20 minutes
Lower limit of cooling
temperature
Remote controller registers
20 minutes independently.
POWERFUL
ON
POWERFUL
OFF
Ending conditions:
1. Lapse of 20 minutes
2. System operation OFF
3. POWERFUL operation OFF
18°C (64.4°F)
Summary of Contents for FDMQ12RVJU
Page 18: ...SiUS091601EA 13 Part 2 Specifications 1 Specifications 14 Part 2 Specifications ...
Page 198: ...Check SiUS091601EA 193 Part 6 Service Diagnosis 18 24 class R24538 1 2 3 4 Multimeter ...
Page 201: ...SiUS091601EA Check Part 6 Service Diagnosis 196 18 24 class R24539 DC DC W V U ...
Page 229: ...SiUS091601EA Piping Diagrams Part 8 Appendix 224 RXL15QMVJU RXL18UMVJU 3D100007 3D123368 ...
Page 230: ...Piping Diagrams SiUS091601EA 225 Part 8 Appendix RXL24UMVJU 3D107985A ...