SiUS091601EA
Specifications
Part 2 Specifications
14
1. Specifications
Model
Indoor Unit
FTX09NMVJU
FTX12NMVJU
Outdoor Unit
RXL09QMVJU
RXL12QMVJU
Cooling
Heating
Cooling
Heating
Power Supply
1
, 60 Hz, 208 - 230 V
1
, 60 Hz, 208 - 230 V
Capacity Rated (Min. ~ Max.)
kW
2.64 (1.30 ~ 3.20)
3.20 (1.30 ~ 4.70)
3.20 (1.30 ~ 3.90)
4.00 (1.30 ~ 5.50)
Btu/h
9,000 (4,400 ~ 10,900)
10,900 (4,400 ~ 16,000)
10,900 (4,400 ~ 13,300)
13,600 (4,400 ~ 18,800)
kcal/h
2,270 (1,120 ~ 2,750)
2,750 (1,120 ~ 4,040)
2,750 (1,120 ~ 3,350)
3,440 (1,120 ~ 4,730)
Moisture Removal
gal/h
0.32
—
0.45
—
Running Current (Rated)
A
3.76 - 3.40
3.95 - 3.57
4.36 - 3.94
5.10 - 4.61
Power Consumption Rated (Min. ~ Max.)
W
720 (250 ~ 1,180)
760 (230 ~ 1,440)
870 (280 ~ 1,390)
1,025 (240 ~ 1,660)
Power Factor (Rated)
%
92.1 - 92.1
92.6 - 92.6
96.0 - 96.0
96.7 - 96.7
COP Rated (Min. ~ Max.)
W/W
3.66 (5.20 ~ 2.70)
4.20 (5.64 ~ 3.26)
3.68 (4.64 ~ 2.80)
3.90 (5.42 ~ 3.30)
EER Rated (Min. ~ Max.)
Btu/h·W
12.5 (17.6 ~ 9.2)
14.3 (19.1 ~ 11.1)
12.5 (15.7 ~ 9.6)
13.3 (18.3 ~ 11.3)
SEER / HSPF
20.0
12.5
20.0
12.0
Piping
Connections
Liquid
in. (mm)
1/4 (
6.4)
1/4 (
6.4)
Gas
in. (mm)
3/8 (
9.5)
3/8 (
9.5)
Drain
in. (mm)
5/8 (
16.0)
5/8 (
16.0)
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Max. Interunit Piping Length
ft (m)
65-5/8 (20)
65-5/8 (20)
Max. Interunit Height Difference
ft (m)
49-1/4 (15)
49-1/4 (15)
Chargeless
ft (m)
32-13/16 (10)
32-13/16 (10)
Amount of Additional Charge of
Refrigerant
oz/ft
(g/m)
0.21 (20)
0.21 (20)
Indoor Unit
FTX09NMVJU
FTX12NMVJU
Front Panel Color
White
White
Airflow Rate
H
cfm
(m³/min)
417 (11.8)
403 (11.4)
434 (12.3)
413 (11.7)
M
297 (8.4)
328 (9.3)
311 (8.8)
321 (9.1)
L
244 (6.9)
251 (7.1)
247 (7.0)
258 (7.3)
SL
141 (4.0)
215 (6.1)
145 (4.1)
219 (6.2)
Fan
Type / Motor Output
W
Cross Flow Fan / 21
Cross Flow Fan / 28
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable, Washable, Mildew Proof
Removable, Washable, Mildew Proof
Running Current (Rated)
A
0.25 - 0.23
0.23 - 0.21
0.28 - 0.25
0.25 - 0.23
Power Consumption (Rated)
W
28 - 28
25 - 25
31 - 31
28 - 28
Power Factor (Rated)
%
53.8 - 52.9
52.3 - 51.8
53.2 - 53.9
53.8 - 52.9
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H × W × D)
in. (mm)
11-1/4 × 30-5/16 × 8-3/4 (285 × 770 × 223)
11-1/4 × 30-5/16 × 8-3/4 (285 × 770 × 223)
Packaged Dimensions (H × W × D)
in. (mm)
14-3/16 × 32-11/16 × 12 (360 × 831 × 305)
14-3/16 × 32-11/16 × 12 (360 × 831 × 305)
Weight (Mass)
Lbs (kg)
18 (8)
18 (8)
Gross Weight (Gross Mass)
Lbs (kg)
24 (11)
25 (12)
Sound Pressure
Level
H / M / L / SL
dB(A)
43 / 36 / 30 / 19
43 / 36 / 29 / 25
45 / 37 / 30 / 19
45 / 37 / 30 / 26
Outdoor Unit
RXL09QMVJU
RXL12QMVJU
Casing Color
Ivory White
Ivory White
Heat Exchanger
Fin / Spec. Tube
Waffle Fin (PE) /
7 mm Hi-XD Tube
Waffle Fin (PE) /
7 mm Hi-XD Tube
Compressor
Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Model
1YC23AUXD
2YC36PXD
Motor Output
W
790
1,100
Refrigerant Oil
Type / Charge
oz (L)
FVC50K / 12.4 (0.375)
FVC50K / 21.5 (0.650)
Refrigerant
Type / Charge
Lbs (kg)
R-410A / 2.09 (0.95)
R-410A / 2.09 (0.95)
Airflow Rate
H
cfm
(m³/min)
1,105 (31.3)
922 (26.1)
1,144 (32.4)
1,006 (28.5)
SL
865 (24.5)
777 (22.0)
865 (24.5)
777 (22.0)
Fan
Type / Motor Output
W
Propeller / 18
Propeller / 20
Running Current (Rated)
A
3.51 - 3.17
3.72 - 3.36
4.08 - 3.69
4.85 - 4.38
Power Consumption (Rated)
W
692 - 692
735 - 735
839 - 839
997 - 997
Power Factor (Rated)
%
94.8 - 94.9
95.1 - 95.1
98.9 - 98.9
98.9 - 99.0
Starting Current
A
3.95
4.94
Dimensions (H × W × D)
in. (mm)
21-5/8 × 26-9/16 × 11-3/16 (550 × 675 × 284)
21-5/8 × 26-9/16 × 11-3/16 (550 × 675 × 284)
Packaged Dimensions (H × W × D)
in. (mm)
24-3/4 × 32-11/16 × 16 (629 × 830 × 407)
24-3/4 × 32-11/16 × 16 (629 × 830 × 407)
Weight (Mass)
Lbs (kg)
60 (27)
70 (32)
Gross Weight (Gross Mass)
Lbs (kg)
71 (32)
80 (36)
Sound Pressure Level
H
dB(A)
49
49
50
50
Conditions Based on
Indoor ; 80°FDB (26.7°CDB)
/ 67°FWB (19.4°CWB)
Outdoor ; 95°FDB (35°CDB)
/ 75°FWB (24°CWB)
Piping Length: 25 ft (7.5 m)
Indoor ; 70°FDB (21°CDB) /
60°FWB (15.6°CWB)
Outdoor ; 47°FDB
(8.3°CDB) / 43°FWB
(6°CWB)
Piping Length: 25 ft (7.5 m)
Indoor ; 80°FDB (26.7°CDB)
/ 67°FWB (19.4°CWB)
Outdoor ; 95°FDB (35°CDB)
/ 75°FWB (24°CWB)
Piping Length: 25 ft (7.5 m)
Indoor ; 70°FDB (21°CDB) /
60°FWB (15.6°CWB)
Outdoor ; 47°FDB
(8.3°CDB) / 43°FWB
(6°CWB)
Piping Length: 25 ft (7.5 m)
Drawing No.
C: 3D101720
C: 3D101721
Notes
SL: The quiet fan level of the airflow rate setting.
SL: The quiet fan level of the airflow rate setting.
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Summary of Contents for FDMQ12RVJU
Page 18: ...SiUS091601EA 13 Part 2 Specifications 1 Specifications 14 Part 2 Specifications ...
Page 198: ...Check SiUS091601EA 193 Part 6 Service Diagnosis 18 24 class R24538 1 2 3 4 Multimeter ...
Page 201: ...SiUS091601EA Check Part 6 Service Diagnosis 196 18 24 class R24539 DC DC W V U ...
Page 229: ...SiUS091601EA Piping Diagrams Part 8 Appendix 224 RXL15QMVJU RXL18UMVJU 3D100007 3D123368 ...
Page 230: ...Piping Diagrams SiUS091601EA 225 Part 8 Appendix RXL24UMVJU 3D107985A ...