12/13
Breadcrumb
Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.I
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
9.I
[D-09]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
6: 100 pulse/kWh (PV meter)
7: 1000 pulse/kWh (PV meter)
9.I
[D-0A]
0
9.I
[D-0B]
2
9.I
[D-0C]
0
9.I
[D-0D]
0
9.I
[D-0E]
0
9.I
[E-00]
R/O
0~5
0: LT split
9.I
[E-01]
R/O
0
9.I
[E-02]
R/W (*1)
R/O (*2)
0: Reversible (*1)
1: Heating only (*2)
9.I
[E-03]
R/O
(*4,*5,*6)
R/W (*7)
0: no heater (*7)
2: 3V (*4)
3: 6V (*5)
4: 9W (*6)
9.I
[E-04]
R/O
0: No
1: Yes
9.I
[E-05]
R/O
0: No
1: Yes
9.I
[E-06]
1
9.I
[E-07]
R/W
0~8
0 OSO tank 150/180
1 FS with BUH
2 FS with BSH
3 OSO tank 200/250/300
4 Rotex without BSH (HYB)
5 Rotex with BSH
6 Third party tank for HYB
7 Third party tank, coil >= 1,05m2
8 Third party tank, coil >= 1,8m2
9.I
[E-08]
R/W
0: No
1: Yes
9.I
[E-09]
1
9.I
[E-0B]
R/W
0: not installed
1: -
2: Bizone kit installed
9.I
[E-0C]
R/W
0: Without hydraulic separator / no
direct pump
1: With hydraulic separator / no direct
pump
2: With hydraulic separator / with direct
pump
9.I
[E-0D]
R/W
0: No
1: Yes
9.I
[E-0E]
0
9.I
[F-00]
R/W
0: Restricted
1: Allowed
9.I
[F-01]
R/W
10~35°C, step: 1°C
20°C
9.I
[F-02]
3
9.I
[F-03]
5
9.I
[F-04]
0
9.I
[F-05]
0
9.I
[F-06]
R/W
0: Disabled
1: Enabled
9.I
[F-07]
R/W
0: Enabled
1: Disabled
9.I
[F-08]
R/W
0: Disabled
1: Enabled
9.I
[F-09]
R/W
0: Disabled
1: Enabled
9.I
[F-0A]
0
9.I
[F-0B]
R/W
0: No
1: Yes
9.I
[F-0C]
R/W
0: No
1: Yes
9.I
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
9.I
[F-0E]
R/W
10~35 kW, step: 1kW
20 kW
Bi-zone kit settings
9.P.1
[E-0B]
R/W
0: not installed
1: -
2: Bizone kit installed
Which type of compressor is installed?
Is an external kWh meter used for power measurement?
--
Pump operation allowed outside range.
--
--
What is the indoor unit software type?
--
What kind of DHW tank is installed?
Is the power saving function available on the outdoor unit?
Which type of unit is installed?
--
--
Continuous heating defrost enable
Is a bi-zone kit installed?
Pump operation during flow abnormality.
--
Close shut-off valve during thermo OFF?
Bi-zone kit installed
Is the system filled with glycol ?
Enable Tank Boiler?
Efficiency calculation
What bizone system type is installed?
Can the system prepare domestic hot water?
Is an external kWh meter used for power measurement, kWh meter used for smart
grid?
--
--
--
What is the number of backup heater steps?
What is the pump operation mode?
Above which outdoor temperature is cooling allowed?
--
--
Power saving function for outdoor unit.
--
Close shut-off valve during cooling?
Tank heating support_max
4P681207-1A - 2022.03
(*1) 300 Tank_(*2) 500 Tank_
(*3) *X*_(*4) *H*_(*5) *B*_
(*6) *EKECBUA3V*_(*7) *EKECBUA6V*_(*8) *EKECBUA9W*_(*9) BUH less_
(*10) 04P_(*11) 08P