17
|
Technical data
Installer reference guide
284
ERGA04~V3A+V37 + EHSH/X(B)04+08P30+50EF
Daikin Altherma 3 R ECH₂O
4P678716-1A – 2022.07
17.5 ESP curve: Indoor unit
Note:
A flow error will occur when the minimum water flow rate is not reached.
0
40
80
60
20
30
70
50
10
A (kPa)
B (l/min)
0
5
10
15
20
25
30
35
C
D E
A
External static pressure in the space heating/cooling circuit
B
Water flow rate through the unit in the space heating/cooling circuit
C
Minimum water flow rate during normal operation
D
Minimum water flow rate during Cooling operation
E
Minimum water flow rate during Heating/Defrost and Backup-Heater operation
Dashed lines:
Operation area is extended to lower flow rates only in case the unit
operates with heat pump only. (Not in startup, no backup heater operation, no
defrost operation.)
Notes:
▪
Selecting a flow outside the operating area can damage the unit or cause the unit
to malfunction. See also the minimum and maximum allowed water flow range in
the technical specifications.
▪
Make sure water quality complies with EU directive 2020/2184.
17.6 Name plate: Indoor unit
MAX.
=
A
p(R32)
≤
4.6
a
MP
a
d
e
f
g
h
i
k
l
n
v
w
o
q
t
u
=
kg
MFG.
.:
NO
MADE IN:
PMS =
PM =
W
V =
V
=
T
=
max
Q =
st
pH O =
2
MPa
l
°C
kWh/24h
MPa
MPa
;
Germany
MFG. DATE :
=
kg
*0
14
00
00
71
43
30
*
p
c
b
j
U = ~ 230 V 50 Hz
/
m
l
=
R32
s
r
a
Modelname
b
Manufacturing number
c
Manufacturing date
d
Empty weight
e
Total filled weight
f
Max. operating pressure PMS (heating circuit)
g
Water volume (storage tank)
h
Max. operating temperature T
max
(storage tank water)
i
Standby heat loss in 24 hours at 60°C (storage tank) Q
st
j
Operating pressure of storage water pH
2
O
k
Domestic hot water volume (heat exchanger)
l
Max. operating pressure PMS (drinking water installation)
m
Nominal voltage U
n
Rated current of fuse
o
Protection type
p
Backup heater (optional)
q
Refrigerant circuit