6/13
Breadcrumb
Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
└─ Tank
9.1.B.1
[6-0D]
R/W
0: Reheat only
3 scheduled reheat
9.1.B.2
[6-0A]
R/W
30~[6-0E]°C, step: 1°C
60°C
9.1.B.3
[6-0B]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
9.1.B.4
[6-0C]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
9.1.B.5
[6-08]
R/W
2~20°C, step: 1°C
10°C
└─ Domestic hot water
9.2.1
[E-05]
[E-06]
[E-07]
R/O
HPSU 'Integrated'
9.2.2
[D-02]
R/W
0: No DHW pump
1: Instant hot water
2: Disinfection
3: Circulation
4: Circulation and disinfection
9.2.4
[D-07]
R/W
0: No
1: Yes (DHW)
2: Yes (DHW + SH)
└─ Back up heater
9.3.1
[E-03]
R/O
(*4,*5,*6)
R/W (*7)
0: no heater (*7)
2: 3V (*4)
3: 6V (*5)
4: 9W (*6)
9.3.2
[5-0D]
R/O
0: 230V, 1~ (*4, *5, *7)
2: 400V, 3~ (*6)
9.3.3
[4-0A]
R/W (*5,
*6, *7)
R/O (*4)
0: 1 (*4, *7)
1: 1/1+2 (*5, *6)
2: 1/2
3: 1/2 + 1/1+2 in emergency
9.3.4
[6-03]
R/W
0~10kW, step: 0,2kW
0kW
2kW (*5)
3kW (*4, *6, *7)
9.3.5
[6-04]
R/W (*5,
*6)
R/O (*4,
*7)
0~10kW, step: 0,2kW
0kW (*4)
3kW (*7)
4kW (*5)
6kW (*6)
9.3.6
[5-00]
R/W
0: No
1: Yes
9.3.7
[5-01]
R/W
-15~35°C, step: 1°C
0°C
9.3.8
[4-00]
R/W
0: Restricted
1: Allowed
2: Only DHW
└─ Booster heater
9.4.1
[6-02]
R/W
0~10kW, step: 0,2kW
0kW
9.4.3
[8-03]
R/W
20~95 min, step: 5 min
50 min
9.4.4
[4-03]
R/W
0: Restricted
1: Allowed
2: Overlap
3: Compressor off
4: Legionella only
└─ Emergency
9.5.1
[4-06]
R/W
0: Manual
1: Automatic
2: Auto red SH/ DHW ON
3: Auto red SH/ DHW OFF
4: Auto normal SH/ DHW OFF
9.5.2
[7-06]
R/W
0: Disabled
1: Enabled
└─ Balancing
9.6.1
[5-02]
R/W
0: Disabled
1: Enabled
9.6.2
[5-03]
R/W
-15~35°C, step: 1°C
0°C
9.6.3
[5-04]
R/W
0~20°C, step: 1°C
10°C
9.6.4
[8-02]
R/W
0~10 hour, step: 0,5 hour
0,5 hour
9.6.5
[8-00]
R/W
0~20 min, step 1 min
1 min
9.6.6
[8-01]
R/W
5~95 min, step: 5 min
30 min
9.6.7
[8-04]
R/W
0~95 min, step: 5 min
95 min
Installer settings
9.7
[4-04]
R/W
0: Continuous pump operation
1: Non continuous pump operation
2: OFF
└─ Benefit kWh power supply
9.8.2
[D-00]
R/W
0: None
1: BSH only
2: BUH only
3: All
9.8.3
[D-05]
R/W
0: No
1: Yes
Heat up mode
Comfort setpoint
Eco setpoint
Reheat setpoint
Reheat hysteresis
Domestic hot water
DHW pump
Solar
BUH type
Voltage
Configuration
Capacity step 1
Additional capacity step 2
Equilibrium: Deactivate backup heater (or external backup heat source in case of a
bivalent system) above the equilibrium temperature for space heating?
Equilibrium temperature
Operation
Capacity
BSH eco timer
Operation
Emergency
Allow heater
Allow pump
Compressor forced OFF
Space heating priority
Priority temperature
Offset BSH setpoint
Anti-recycle timer
Minimum running timer
Maximum running timer
Additional timer
Water pipe freeze prevention