7
|
Unit installation
Installer reference guide
89
ERGA04~V3A+V37 + EHSH/X(B)04+08P30+50EF
Daikin Altherma 3 R ECH₂O
4P678716-1A – 2022.07
a
a
c
c
b
1
3
2
a
Screw plug
b
Assembly wrench
c
Spillover connector
2
Insert the spillover connector into the screw plug.
3
Mount the spillover connector.
4
Attach a drain hose to the spillover connector.
5
Connect the drain hose to an appropriate drain. Ensure the water can flow
through the drain hose. Ensure that the water level cannot mount above the
overspill.
6
Connect the drain pan hose to the drain pan connection and connect to an
appropriate drain.
a
a
Drain pan hose
7
Connect the pressure relief valve to an appropriate drain in accordance with
the applicable legislation. Ensure that any steam or water that may escape is
drained in a frost-protected, safe and observable manner.