![background image](http://html.mh-extra.com/html/daikin/arkh20cvmb7/arkh20cvmb7_service-manual_501299171.webp)
Outdoor Unit / ARK(X)S-C
SiENBE04-512A
162
Removal Procedure
2. Outdoor Unit / ARK(X)S-C
2.1
Removal of Panels and Fan Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Features
Take care not to cut your
finger by the fins of the heat
exchanger.
The stop valve cover is
united with the shelter.
When reassembling, make
sure to fit the 5 hooks.
1
Loosen the screw of the
stop valve cover.
Pull down the stop
valve cover and remove
it.
H
a
ndle
(R
3
2
3
5)
O
u
tdoor
a
ir
thermi
s
tor
(R
3
2
3
6)
S
top
v
a
lve
cover
(R
3
2
3
7)
S
helter
Hook
s
(R
3
2
38
)
SiENBE04-512A.book Page 162 Friday, October 5, 2007 1:49 PM
Summary of Contents for ARKH20CVMB7
Page 1: ...SiENBE04 512A Service Manual Inverter Pair Wall Mounted Type C Series D Series ...
Page 17: ...List of Functions SiENBE04 512A 8 List of Functions ...
Page 37: ...Specifications SiENBE04 512A 28 Specifications ...
Page 73: ...Control Specification SiENBE04 512A 64 Function and Control ...
Page 103: ...Instruction SiENBE04 512A 94 System Configuration ...
Page 147: ...Check SiENBE04 512A 138 Service Diagnosis ...
Page 225: ...Outdoor Unit RK X H C ARK X H C R Y N C SiENBE04 512A 216 Removal Procedure ...
Page 229: ...Others SiENBE04 512A 220 Others ...
Page 241: ...Wiring Diagrams SiENBE04 512A 232 Appendix ...