Printed Circuit Board Connector Wiring Diagram
SiENBE04-512A
30
Printed Circuit Board Connector Wiring Diagram
1. Printed Circuit Board Connector Wiring Diagram
1.1
Indoor Unit
Connectors
Note:
Other designations
1) S1
Connector for fan motor
2) S6
Connector for swing motor (horizontal blades)
3) S7
Connector for fan motor (Hall IC)
4) S21
Connector for centralized control (HA)
5) S26
Connector for signal receiver PCB
6) S27, S36
Connector for control PCB
7) S32
Connector for heat exchanger thermistor
8) S35
Connector for INTELLIGENT EYE sensor PCB (Inverter models only)
1) V1
Varistor
2) JA
Address setting jumper
JB
Fan speed setting when compressor is OFF on thermostat
JC
Power failure recovery function (auto-restart)
∗
Refer to page 219 for detail.
3) SW7
Forced operation ON / OFF switch
4) LED1
LED for operation (green)
5) LED2
LED for timer (yellow)
6) LED3
LED for HOME LEAVE operation (red) (Inverter models only)
7) LED A
LED for service monitor (green)
8) FU1
Fuse (3.15A)
9) RTH1
Room temperature thermistor
SiENBE04-512A.book Page 30 Friday, October 5, 2007 1:49 PM
Summary of Contents for ARKH20CVMB7
Page 1: ...SiENBE04 512A Service Manual Inverter Pair Wall Mounted Type C Series D Series ...
Page 17: ...List of Functions SiENBE04 512A 8 List of Functions ...
Page 37: ...Specifications SiENBE04 512A 28 Specifications ...
Page 73: ...Control Specification SiENBE04 512A 64 Function and Control ...
Page 103: ...Instruction SiENBE04 512A 94 System Configuration ...
Page 147: ...Check SiENBE04 512A 138 Service Diagnosis ...
Page 225: ...Outdoor Unit RK X H C ARK X H C R Y N C SiENBE04 512A 216 Removal Procedure ...
Page 229: ...Others SiENBE04 512A 220 Others ...