Main Functions
SiENBE04-512A
36
Function and Control
1. Main Functions
Note:
See the list of functions for the functions applicable to different models.
1.1
Frequency Principle
Main Control
Parameters
The compressor is frequency-controlled during normal operation. The target frequency is set by
the following 2 parameters coming from the operating indoor unit:
The load condition of the operating indoor unit
The difference between the room temperature and the set temperature
Additional
Control
Parameters
The target frequency is adapted by additional parameters in the following cases:
Frequency restrictions
Initial settings
Forced cooling operation
Inverter Principle
To regulate the capacity, a frequency control is needed. The inverter makes it possible to vary
the rotation speed of the compressor. The following table explains the conversion principle:
Drawing of
Inverter
The following drawing shows a schematic view of the inverter principle:
Phase
Description
1
The supplied AC power source is converted into the DC power source for the present.
2
The DC power source is reconverted into the three phase AC power source with variable
frequency.
When the frequency increases, the rotation speed of the compressor increases resulting
in an increased refrigerant circulation. This leads to a higher amount of the heat
exchange per unit.
When the frequency decreases, the rotation speed of the compressor decreases
resulting in a decreased refrigerant circulation. This leads to a lower amount of the heat
exchange per unit.
Refriger
a
nt circ
u
l
a
tion r
a
te (high)
high f
low f
fre
q
=v
a
ri
ab
le
Refriger
a
nt circ
u
l
a
tion r
a
te (low)
high
s
peed
low
s
peed
(R2
8
12)
Amo
u
nt of he
a
t
exch
a
nged
a
ir (l
a
rge)
Amo
u
nt of he
a
t
exch
a
nged
a
ir (
s
m
a
ll)
Amo
u
nt of he
a
t
exch
a
nged
a
ir (l
a
rge)
Amo
u
nt of he
a
t
exch
a
nged
a
ir (
s
m
a
ll)
c
a
p
a
city=
v
a
ri
ab
le
fre
q
=
con
s
t
a
nt
50 Hz
50 Hz
60 Hz
60 Hz
AC
po
w
e
r
DC
po
w
e
r
SiENBE04-512A.book Page 36 Friday, October 5, 2007 1:49 PM
Summary of Contents for ARKH20CVMB7
Page 1: ...SiENBE04 512A Service Manual Inverter Pair Wall Mounted Type C Series D Series ...
Page 17: ...List of Functions SiENBE04 512A 8 List of Functions ...
Page 37: ...Specifications SiENBE04 512A 28 Specifications ...
Page 73: ...Control Specification SiENBE04 512A 64 Function and Control ...
Page 103: ...Instruction SiENBE04 512A 94 System Configuration ...
Page 147: ...Check SiENBE04 512A 138 Service Diagnosis ...
Page 225: ...Outdoor Unit RK X H C ARK X H C R Y N C SiENBE04 512A 216 Removal Procedure ...
Page 229: ...Others SiENBE04 512A 220 Others ...
Page 241: ...Wiring Diagrams SiENBE04 512A 232 Appendix ...