1.7
INTELLIGENT EYE
This is the function that detects existence of humans in the room by a human motion sensor
(INTELLIGENT EYE) and reduces the capacity when there is no human in the room in order to
save electricity.
Processing
1. Detection method by Intelligent Eye
This sensor detects human motion by receiving infrared rays and displays the pulse wave
output.
A microcomputer in an indoor unit carries out a sampling every 20 msec. and if it detects 10
cycles of the wave in one second in total (corresponding to 20msec.× 10 = 100msec.), it
judges human is in the room as the motion signal is ON.
2. The motions (for example: in cooling)
When a microcomputer doesn’t have a signal from the sensor in 20 minutes, it judges that
nobody is in the room and operates the unit in temperature sifted 2°C from the set
temperature. (Cooling : 2°C higher, Dry: 1°C higher and Auto : according to the operation
mode at that time.)
H
1 In case of Fan mode, the fan speed reduces by 50 rpm.
1
s
ec
sa
mpling (20m
s
ec)
High
Low
ON
OFF
S
en
s
or o
u
tp
u
t
(H
u
m
a
n motion)
(R2
8
21)
H
u
m
a
n detection
s
ign
a
l
If the
s
en
s
or detect
s
the o
u
tp
u
t
s
10 time
s
/
s
ec.
or more, it j
u
dge
s
h
u
m
a
n
s
exi
s
t.
ON
OFF
RE
S
ET.
Cooling :
S
et temp. + 2°C
He
a
ting :
S
et temp. - 2°C
20 min.
20 min.
within 20
min
u
te
s
.
40 min.
M
a
xHz
Mi nHz
0Hz
ON
OFF
ON
OFF
Oper
a
tion
OFF
F
a
n
s
peed (
H
1)
S
et
s
peed - 50 rpm
S
et
s
peed
S
et
s
peed
Fre
qu
ency
a
t
s
et temp. + 2°C
S
et temp.
(R4902)
Remote control
Intelligent Eye
bu
tton
The lower limit
b
y detecting
h
u
m
a
n.
(Prohi
b
ition of thermo
s
t
a
t-off)
in c
as
e of
thermo
s
t
a
t-off
Compre
ss
or
s
peed
H
u
m
a
n detection
s
ign
a
l
SiENBE04-512A.book Page 43 Friday, October 5, 2007 1:49 PM
Summary of Contents for ARKH20CVMB7
Page 1: ...SiENBE04 512A Service Manual Inverter Pair Wall Mounted Type C Series D Series ...
Page 17: ...List of Functions SiENBE04 512A 8 List of Functions ...
Page 37: ...Specifications SiENBE04 512A 28 Specifications ...
Page 73: ...Control Specification SiENBE04 512A 64 Function and Control ...
Page 103: ...Instruction SiENBE04 512A 94 System Configuration ...
Page 147: ...Check SiENBE04 512A 138 Service Diagnosis ...
Page 225: ...Outdoor Unit RK X H C ARK X H C R Y N C SiENBE04 512A 216 Removal Procedure ...
Page 229: ...Others SiENBE04 512A 220 Others ...
Page 241: ...Wiring Diagrams SiENBE04 512A 232 Appendix ...