Removal Procedure
163
2. Remove the panels.
1
Loosen the 3 screws
(front, right, left) and lift
the top panel.
2
Remove the drip proof
plate.
3
Disconnect the
connector for fan motor
(S70).
The fan motor is united with
the front panel.
4
Loosen the 5 screws of
the front panel.
Step
Procedure
Points
Top p
a
nel
(R
3
2
3
9)
Drip proof pl
a
te
(R
3
240)
S
70
(R
3
241)
Front p
a
nel
(R
3
242)
SiENBE04-512A.book Page 163 Friday, October 5, 2007 1:49 PM