manualshive.com logo in svg
background image

Swiss Made

www. iqair. com

User’s Manual

HealthPro® Compact

All manuals and user guides at all-guides.com

all-guides.com

Содержание HealthPro Compact

Страница 1: ...Swiss Made www iqair com User s Manual HealthPro Compact All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...n facility IQAir assembly line Final system assembly Filters awaiting final sealing process Filter quality control of a HyperHEPA filter Control panel assembly Final inspection and packaging Individual performance testing and certification All manuals and user guides at all guides com ...

Страница 3: ...ar appliances Only use this appliance for its intended purpose of air cleaning in non industrial environments Do not use this appliance in areas with very high concentrations of dust or powder to prevent the danger of dust explosions Do not use this appliance in explosive areas Do not use attachments or filters not recommended by IQAir Do not use outdoors Do not obstruct the air inlet and air outl...

Страница 4: ...All manuals and user guides at all guides com ...

Страница 5: ...4 4 4 Day of the Week Timer 14 4 4 5 Timer ON OFF Fan Speed Selection Menu 14 4 4 6 Timer Information in the Control Panel 15 4 4 7 Time Day Setting 16 4 4 8 Filter Life Reset 16 4 4 9 Changing the Airflow Units 17 4 4 10 Language Setting 17 Chapter 5 Using the Remote Control 18 5 1 Description of Remote Control Elements and Functions 18 5 2 Getting the Best Transmission Results 18 5 3 Replacing t...

Страница 6: ...irements are stringent the hourly air delivery of the system needs to exceed the room air volume several times To achieve that level of air turnover it may be necessary to employ more than one IQAir system or employ an IQAir HVAC filtration system Air Cleaning Results Although air cleaners may be advertised and sold to be suitable for use in specific indoor environments and to deal with specific i...

Страница 7: ...oms at the various fan speed settings DVD IQAir Advanced Air Cleaning System Set of casters Remote control including battery Classification EN1822 Class H13 at 0 112 cfm Media wet laid glass Large capacity pre filter Purpose control of coarse and fine dust particles Media wet laid nonwoven glass microfiber mini pleated Surface area 15 sq ft Efficiency 99 efficient at 5m m Wide spectrum gas and odo...

Страница 8: ...sawalloracupboard Ingeneral themorecentrallythesystemispositioned thebettertheperformance Position the system close to a power outlet and make sure that the power cord is positioned in a way that it does not present an obstacle in walkways Make sure that the system is positioned in such a way that the control panel is easily accessible 2 3 Connecting to Power 1 Plug the connector end of the power ...

Страница 9: ...ened the locking arms allow easy access to all filters The handle on top of the diffuser is designed for carrying the IQAir system The EvenFlow diffuser contains omni directional air outlet openings The HyperHEPA filter module consists of frame 2 and the HyperHEPA filter The Fan Assembly comprises two housing modules with the centrifugal fan inside The Pre Max Filter module consists of frame 1 and...

Страница 10: ...PA media The HEPA filter captures the finest of particles 5 Low turbulence low velocity air is returned to the room via the EvenFlow diffuser 3 2 Description of Removable Components The IQAir system features a modular housing design which enables the easy replacement of all filter elements in a matter of seconds The illustration below shows all the removable components For more details on how to r...

Страница 11: ...an be completed via the electronic control panel Switching the system on and off Controlling the fan speed and corresponding air delivery rate Checking the remaining filter life of the individual filters Setting the automatic timer Resetting the Filter Life Monitor after replacing a filter Locking the control panel to avoid tampering with the system s settings Choosing the desired display language...

Страница 12: ...r a reduction in filter efficiency gas phase filter is saturated Fan Speed LEDs These LEDs simulate the fan speed through the frequency of their rotation The faster the rotation of the fan speed LEDs the faster the actual fan speed of the unit 4 2 Control Panel Locking Function The control panel keys can be locked to avoid tampering with the settings To lock or unlock the control panel keys the Me...

Страница 13: ...ic environment are calculated as follows hourly air delivery of the IQAir system cfm cubic feet per minute air changes per hour ACH air volume of the room cu ft Note The air delivery rates of the IQAir system at the various fan speeds settings are listed on the Technical Specifications sheet Example calculation A room with the dimensions of 13 x 14 x 8 5 ft has an air volume of 1 547 cu ft With an...

Страница 14: ...the current speed setting How the Filter Life Monitor Works The basis for the calculation of the remaining filter life is the already elapsed operation time at the set fan speed This input is compared with an internal memory bank which contains information about the different filters lives under specific conditions of use The Filter Life Monitor makes a calculation of the remaining filter life tak...

Страница 15: ...hold the Enter key until the cursor starts to flash 3 Press the key one time to activate the timer Note If the START and STOP times are identical the timer cannot be activated 4 Press the Enter key to save the timer status setting and to proceed to the START time 5 Select the desired START hour by pressing the key 6 Press the Enter key to save the START hour and to proceed to the minute setting 7 ...

Страница 16: ... 4 Day of the Week Timer The Day of the Week Timer allows the deactivation of the Timer ON period on certain days of the week In its default setting the Timer ON period is enabled on all seven days of the week This is indicated by stars below the abbreviations of the days On days without a star the air cleaner will be running at the speed which is set in the Timer OFF Speed Selection Menu see 4 4 ...

Страница 17: ...fan speed and the second line shows the airflow The Timer LED is off System on Standby The first line shows the current day time and and the second line shows the next time the system will turn on TheTimer LED is green System Running The first line shows the fan speed and the second line shows when the system will switch to the Timer OFF period The Timer LED is green System is running Timer is dea...

Страница 18: ...t unaffected 5 To confirm the filter change and exit the Filter Life Reset display window press the Enter key 6 Upon successful reset of the filter life the new remaining filter life taking the currently selected fan speed into account will be displayed and the filter LED light on the control panel will change from red to green 4 4 7 Time Day Setting When the IQAir system is first connected to the...

Страница 19: ... to exit the enter mode 17 Chapter 4 Using the Control Panel 4 4 9 Changing the Airflow Units 1 You can change the airflow units which are displayed from cubic feet per minute cfm to cubic meters per hour m3 h and vice versa by pressing the Enter key for three seconds either when the unit is switched on or in standby mode 2 When the first character of the airflow units starts to flash press the ke...

Страница 20: ...set in the Daily Timer Menu it is possible to switch the timer on and off with the remote control To switch the timer on press the Timer Modification key and then the Timer ON key To switch the timer off press the Timer Modification key and then the Timer OFF key 5 2 Getting the Best Transmission Results The IR infrared receiver of the IQAir system is positioned underneath the control panel cover ...

Страница 21: ...orrespond to the actual positions of the filter elements within the system 19 Chapter 6 Replacing Filters 5 3 Replacing the Remote Control Battery When the battery becomes weak the transmission results will deteriorate and the battery should be replaced The remote control requires one CR2025 battery The battery compartment is located at the bottom end of the remote control To open the battery comp...

Страница 22: ...position in the diffuser Disengage the other arm in the same way 3 Pull both locking arms evenly outwards until they snap into place and remain open Access to all filter elements is now possible to change a specific filter refer to the appropriate section below 4 To close the housing align the housing elements and simply push the locking arms inwards simultaneously until they snap back into the ho...

Страница 23: ...or details on how to close the housing please refer to section 6 3 8 Dispose of the used filter by placing it into the plastic bag in which the new filter is supplied 7 Lift the frame from the filter 10 Make sure that the filter is inserted all the way into the frame Insert the clamps into the sliding grooves inside the frame and push them down If known harmful substances are filtered please refer...

Страница 24: ...section 6 6 9 Put frame 2 back into the housing and reposition the diffuser For closing refer to section 6 3 Frame 2 6 6 Discarding Used Filters Used filter elements can normally be put into the regular household trash for disposal If the system may have been exposed to potentially hazardous substances the filters may have to be disposed of as hazardous waste Please refer to local regulations and ...

Страница 25: ... period please contact your point of purchase or call IQAir Technical Support at 888 560 1020 toll free or e mail support iqair com To expedite your service request please have the following information ready when contacting us 1 IQAir model shell number and serial number found at the base of the unit and on the certificate 2 Your details name address phone number e mail 3 Point of purchase name o...

Страница 26: ...re subject to change without prior notice 105 01 00 27 0407 tolerance 10 10 cfm 700 cfm 2750 rpm centrifugal backward curved UL CSA registered 120 Volt 60 Hz 215 w 4 key touch pad with 32 character LCD display 320 diffuser Dual arches at base of unit light grey white yes non offgasing impact resistant UV stabilized ABS English default French German Italian Spanish yes greater than 99 97 for partic...

Отзывы: