9
|
Configuration
Installer reference guide
186
EPRA14~W1 + ETVH/9W(G)
Daikin Altherma 3 H HT F
4P587502-1A – 2020.01
Priority heater
#
Code
Description
[9.9.D]
[4-01]
Power consumption control DISABLED
[4‑08]=0
▪
0
None
: Backup heater and booster heater
can operate simultaneously.
▪
1
Booster heater
: The booster heater is
prioritised.
▪
2
Backup heater
: The backup heater is
prioritised.
Power consumption control ENABLED
[4‑08]=1/2
▪
0
None
: Depending on the power limitation
level, the booster heater will be limited first,
before the backup heater is limited.
▪
1
Booster heater
: Depending on the
power limitation level, the backup heater will
be limited first, before the booster heater is
limited.
▪
2
Backup heater
: Depending on the power
limitation level, the booster heater will be
limited first, before the backup heater is
limited.
Note:
In case power consumption control is DISABLED (for all models) the setting
[4‑01] defines whether backup heater and booster heater can operate
simultaneously, or if the booster heater/backup heater has priority over the
backup heater/booster heater.
In case power consumption control is ENABLED, the setting [4‑01] defines the
priority of the electrical heaters depending on applicable limitation.
BBR16
See
"5.6.4 BBR16 power limitation"
53] for detailed information about this
functionality.
INFORMATION
Restriction:
BBR16 settings are only visible when the language of the user interface is
set to Swedish.
NOTICE
2 weeks to change.
After you activated BBR16, you only have 2 weeks to change its
settings (
BBR16 activation
and
BBR16 power limit
). After 2 weeks, the unit
freezes these settings.
Note:
This is different from the permanent power limitation, which is always
changeable.