Pilot's Operating Handbook
Section 7
Description
Edition 0 - October 31, 2013
Rev. 5
Page 7.14.2
Cabin fire extinguisher
The fire extinguisher is located on R.H. front station side panel.
A pressure gage allows checking the fire extinguisher condition. Follow the
recommendations indicated on the extinguisher.
Autopilot
Autopilot control panel is located above the MFD. Refer to section 2 Limitations of this
POH and to GARMIN Pilot's Guide for further details.
GPS
GPS navigation is performed through the GARMIN system. Refer to section 2
Limitations and section 4 Normal procedures of this POH and to GARMIN Pilot's
Guide for further details.
Emergency locator transmitter
The airplane is equipped with an emergency locator transmitter which enables to
locate it in case of distress. It is located in fuselage rear section with a service door on
fuselage R.H. side.
The emergency locator transmitter assembly is constituted of a transmitter supplied
by a battery, of an antenna attached on upper fuselage and of a remote control located
on the upper panel.
●
NOTE
●
For test sequences, refer to manufacturer manual.
●
>> ELT ARTEX C406-1
Operation of the emergency locator transmitter is obtained as follows :
-
from the instrument panel by setting ELT remote control switch to ON (locator
transmitter ON/OFF switch set to OFF),
-
from the locator transmitter by setting its ON/OFF control switch to ON,
-
automatically in case of shock, when remote control switch is set to ARM and
locator transmitter switch is set to OFF.
A red indicator light located on ELT remote control switch in the cockpit indicates to the
pilot the emergency locator transmitter is transmitting.
A red indicator light located above locator transmitter switch and a buzzer located in
the fuselage rear section indicate the emergency locator transmitter is transmitting.
PIM - DO NOT USE FOR FLIGHT OPERATIONS